Instruction manual

4
2.5 SPECIFICATIONS
Output Specification
Model VSP6020* VSP2050* VSP4030* VSP12010*
Power 1.2KW 1.2KW 1.2KW 1.2KW
Output Voltage 0–60V 0–20V 0–40V 0–120V
Output Current 0–20A 0–50A 0–30A 0–10A
Ripple rms. (10Hz to 1MHz) <10mV <15mV <10mV <20mV
Noise (10Hz to 20MHz) <45mVpp <45mVpp <45mVpp <45mVpp
Programming Resolution (Digital Interface), LSB (not LED displays)
Voltage 20 mV 10 mV 10 mV 100 mV
Current 10 mA 20 mA 10 mA 10 mA
Output Programming Accuracy (Analog Programming 0 To 5V & 0 To 10V)
Voltage 0.5 % of F. S. ± 1 Digit (spec. for all VSP models)
Current 0.5 % of F. S. ± 1 Digit (spec. for all VSP models)
Meter Accuracy
Voltage +/- 0.2% of F.S. +/- 3 Digit. (spec. for all VSP models)
Current +/- 0.2% of F.S. +/- 3 Digit. (spec. for all VSP models)
Regulation
CV Line Regulation (mV) 0.1 % of F.S (spec. for all VSP models)
CC Line Regulation (mV) 0.1 % of F.S (spec. for all VSP models)
CV Load Regulation (mA) 0.1 % of F.S (spec. for all VSP models)
CC Load Regulation (mA) 0.1 % of F.S (spec. for all VSP models)
Output Specification
Stability 0.05%
Efficiency
< 80% Minimum
Transient Response 250 microseconds for load change from 40% to 90%
Mode Of Operation
Local Mode Through front panel potentiometer for voltage, current and
over voltage and Push switch for Output ON/ OFF control.
Remote Mode Interface Analog programming of voltage
and current.Voltage: 0 - 5 volts or 0 – 10 volts for output
voltage and current, selection through DIP-switch.
Resistance: 0 – 4.85k ohms from 0 to full-scale level.
Digital Interface RS-232 / GPIB
* = Specification also apply to corresponding GPIB model
F.S = Full Scale. Full scale will be different for each model. Example: If you have a VSP2050
and you are measuring the voltage meter accuracy, the meter can not off more than 0.3V
(20V + 0.2% +3 digit). Note: 3 digits refferes to the power supply displays least significant digit.