138
waveform sequence shown above.
PROG 1
Select program 1
PROG:NEXT 2 Change the NEXT command from
NEXT 0 to NEXT 2
PROG:SAV After edit is complete use Save
command to store changes in the
hardware
PROG 1
PROG:RUN ON
Select program 1
Use RUN ON command to execute
4.4 Multi Unit Programming
The instrument can be connected together with multiple units via
RS-485 interface, as described in section “3.2Remote Interface
Setup” under “RS-485 Interface” and be controlled via a single USB
connection between the PC and one of the power supplies. The
setup is illustrated below:
Figure 30- Multi Unit Programming