User manual

41
FREQuency<ws>MINimum|MAXimum
Examples: FREQ 5KHZ
FREQ 5E3
FREQ MAXIMUM
FREQ MIN
Query
Syntax: FREQuency?[<ws>MAXimum|MINimum]
Examples: FREQ?
FREQ? MAX
Response: NR3
Considerations:
1) The MIN and MAX arguments refer to currently settable minimum or maximum.
2) FIXed is alias for CW.
AMPLitude <p-p amplitude>
The amplitude command is used to set the peak-to-peak amplitude of the output waveform.
Note that the amplitude and the offset are limited by the relation:
Peak Amplitude + |Offset| <= 5V
Arguments
Type: Numeric
Units: V, mV, VPP, mVPP
Range: 10mV to 10V
Rounding: 1mV for 10mV to 999mV. 10mV for 1V to 10V.
Command Type: Setting or Query
Setting
Syntax: AMPLitude<ws><amplitude>[units]
AMPLitude<ws>MINimum|MAXimum
Examples: AMPL 2.5
AMPL 2.5V
AMPL MAX
Query
Syntax: AMPLitude? <ws>MINimum|MAXimum]
Examples: AMPL?
AMPL? MAX
Response: NR2
Considerations:
1) The MAXimum amplitude is dependent on the offset.