User manual
38
510 Output overload
"Trigger rate short" means that the period of the waveform is larger than the value of the
internal trigger rate. Thus not every trigger will generate a cycle (or burst) of the waveform.
4.8 COMMON COMMANDS
4.8.1 System Data Commands
*IDN? - Identification query
The identification query enables unique identification of the device over the GPIB. This query
should always be the last in a program message. It returns a string with four fields:
Manufacturer name
Model name
Serial number (0 if not relevant)
Version number
Command
Type: Common Query
Syntax: *IDN?
Response: BK, MODEL 4040B,0,V1.1
4.8.2 Internal Operation Commands
*RST - Reset command
The Reset command performs a device reset. It causes the device to return to the
factory default power up state.
Type: Common Command
Syntax: *RST
4.8.3 Device Trigger Commands
a) *TRG - Trigger command
This command is analogous to the IEEE 488.1 Group Execute Trigger interface message, and
has the same effect. It is used to trigger the device to output a wave, and is accepted only
when the trigger mode is set to Trigger, Gate or Burst, and the trigger source is set to BUS.
Type: Common Command
Syntax: *TRG