User manual
34 
Reference Command: *ESE *ESR?  *PSC *STB? 
*STB?   
This command reads data from the status byte register. After executing this command, the status byte register is 
reset. 
Query syntax: *STB? 
Parameter: None 
Return parameter: <NR1> 
Reference command:  *CLS *ESE *ESR  
Bit map of the standard event status enable register 
Bit Position 
7 
6 
5 
4 
3 
2 
1 
0 
Bit Name 
OPER 
RQS 
ESB 
no use 
QUES 
no use 
no use 
no use 
Bit Value 
128 
64 
32 
8 
*TRG 
When the power supply’s trigger source is set to Bus command, this command will generate a trigger signal. Its 
function is identical to the [SYSTem:]TRIGger command. 
Command syntax: *TRG 
Parameter: None 
Reference command: TRIG TRIG:SOUR 
*SAV 
This command saves the operating parameters of the power supply to non volatile memory. The parameters 
include constant current, constant voltage, maximum voltage value and step voltage values. 
Command syntax: *SAV<NRf> 
Parameter: 1~50 
Example: *SAV 3 
Reference command: *RCL  
*RCL 
This command recalls the parameter saved with the *SAV command. 
Command syntax: *RCL<NRf> 
Parameter: 1~50 
Example: *RCL 3 
Reference command: *SAV  
Essential SCPI Commands 
SYSTem:ERRor[:NEXT]? 
This command queries the error code and error information of the power supply. 
(0)   No error 
(1)  Too many numeric suffices in Command Spec 
(10)  No Input Command to parse 
(14)  Numeric suffix is invalid value 
(16)  Invalid value in numeric or channel list, e.g. out of range 
(17)  Invalid number of dimensions in a channel list 
(20)  Parameter of type Numeric Value overflowed its storage 
(30)  Wrong units for parameter   
(40)  Wrong type of parameter(s) 
(50)  Wrong number of parameters 