Instruction manual

79
When output voltage becomes equal or greater than OVP trip level (here
is 8V), OVP circuit trips. Output is disabled and Over Voltage message
will be displayed.
VOLT:PROT:STAT OFF ;Disable OVP circuit
Attention: if you have anything connected to the output terminals of the
power supply, it it strongly recommended that you disconnect it before
disabling OVP circuit (because you don’t change output level and this it
may harm your connected circuitry)
VOLT:PROT:STAT? ;returns OVP circuit state (0 off state)
Still output is disabled and Over Voltage message is displayed (because
you didn’t clear OVP condition yet)
VOLT:PROT:CLEAR ;clear OVP condition
Power supply returns to previous state before enabling OVP circuit. It
will display 15V and 0A. Since you disabled OVP circuit, ovp indicator
will not be displayed anymore, until you enable OVP circuit again.