Table 3 - Step Parameter Range
Parameter
Adjustable Range
Voltage Setting
0.000 < OVP Voltage
Current Setting
0.000 *max. current setting
Width
0.001 seconds 86400 seconds
Slope
0.002 seconds 86400 seconds
*Maximum current and voltage setting cannot exceed maximum power configured under P-max setting.
As an example, follow the steps below to set up a sequence with fixed current limit of 1 A, as
illustrated below:
1. Access the main menu by pressing and the .
2. Use the key to select LIST and press . The below screen will display:
3. Use the key to select EditSeq and press . The display will say EDIT SEQ and
an entry for Seq Name: is displayed.
4. Use the current adjust knob or the numeric keypad to select any number between 1
10 to edit its sequence. Press . Now, the following screen will display:
V
S
1
2
3
1 s
2 s
3 s
3 s
4 s
LIST MENU
Off Recall EditList EditSeq