There are three separate configurations to set up for programming and running a sequence (in 
order): 
1.  Configure Sequence Parameters 
2.  Configure Program (List) 
3.  Recall and Run Program 
Note: These configurations must be set up in order.  
The following sections will go into the details of setting up all three configurations. 
Note: It is recommended that the Trigger Source be configured prior to setting up the 
configurations. Additionally, the output of the power supply must be disabled 
prior to setting up the configurations. 
Configure Sequence Parameters 
Each sequence can store from 1 to 10 steps. Each step’s parameters contain voltage setting, 
current setting, width (time to hold the step), and slope (voltage rise and fall). The adjustable 
range for each of these parameters are specified in table below: 
Sequence #1 
Step 1.. 
Step 2.. 
.. 
Step 10.. 
Sequence #10 
Step 1.. 
Step 2.. 
.. 
Step 10.. 
Program #1 
Sequence #1 
Sequence #2 
.. 
Sequence #10 
Program #10 
Sequence #2 
Sequence #5 
Sequence #7 
Sequence #8 
Run 
Program # 
Memory 
Save 
Recall 