User manual

38
Configure Voltage Limit
The minimum and maximum set voltage can be configured on the power supply to limit the
settable voltage range for protection.
Note: At any time during operation, when you are unable to set to a desired voltage,
check this voltage limit setting to make sure the set value is within range.
Follow the steps below to configure the voltage limits:
1. From the CONFIG menu, browse and select Limit and press . The following
screen will display:
2. With Vmin prompted, use the voltage or current adjust knob or the numeric keypad to
enter the minimum voltage limit value.
3. When finished, press , and the display will prompt with Vmax.
4. Enter the maximum voltage limit value the same way as in step 2.
5. When finished, press . The screen will return to the CONFIG menu.
6. Press several times to exit the menu.
Parallel/Series Connection
Up to three 9115 power supplies can be connected together in a parallel or series connection
setup. The power supplies can be set up for master/slave mode so that the master unit can
control all other power supplies in the parallel/series connection.
Note: Master/slave configurations and RS485 connections must be properly set up prior
to controlling the power supplies in parallel/series connection. However, RS-485
does not have to be set as the Communication interface for master/slave operation
Voltage Range
Vmin = 0.000 V