Configure Voltage Limit 
The minimum and maximum set voltage can be configured on the power supply to limit the 
settable voltage range for protection. 
Note: At any time during operation, when you are unable to set to a desired voltage, 
check this voltage limit setting to make sure the set value is within range. 
Follow the steps below to configure the voltage limits: 
1.  From the CONFIG menu, browse and select Limit and press  . The following 
screen will display: 
2.  With Vmin prompted, use the voltage or current adjust knob or the numeric keypad to 
enter the minimum voltage limit value. 
3.  When finished, press  , and the display will prompt with Vmax. 
4.  Enter the maximum voltage limit value the same way as in step 2. 
5.  When finished, press . The screen will return to the CONFIG menu. 
6.  Press   several times to exit the menu. 
Parallel/Series Connection 
Up to three 9115 power supplies can be connected together in a parallel or series connection 
setup. The power supplies can be set up for master/slave mode so that the master unit can 
control all other power supplies in the parallel/series connection. 
Note: Master/slave configurations and RS485 connections must be properly set up prior 
to controlling the power supplies in parallel/series connection. However, RS-485 
does not have to be set as the Communication interface for master/slave operation 
Voltage Range 
Vmin = 0.000  V 