Restore Factory Default Settings
All instrument settings can be reset back to their factory default values by doing the following:
WARNING:
Restoring the instrument to factory default will change all current instrument
settings and parameters back to their default values.
1. From the SYSTEM menu, select Initialize and press .
2. The instrument will return to the normal display and all settings are now restored back
to factory default. The below table lists some of the factory default settings.
Table 2 - Factory Default Settings
Communication Address
0
Key Sound
ON
Trigger Mode
Manual
Communication Interface
RS232
RS232 Settings
4800, 8, N, 1
Return Meter
Off
Memory
Group 0
Power-On
Rst
Load Setup
Off
External Control
10v-M
Limit
Vmin = 0.000V, Vmax = 81.000V
Online Setup
Off
Output
Disabled
Configure Power-On State
The initial power-On state of the power supply can be configured by following the steps below:
1. From the SYSTEM menu, select Power-On and press .
2. There are two options:
Rst(Def)Factory Default.
Sav0Settings before last power up.
3. Select the settings you want during power up, and press to save changes.