User manual
16 
2.  Use a flat blade screwdriver and turn the fuse capsule counter-clockwise. There is an 
internal spring that will push it out after turning a few times. 
3.  Pull out the glass tube fuse inside to check and replace as necessary. 
4.  Insert the fuse capsule in the same location and use the flat blade screwdriver to turn 
clockwise. 
5.  The fuse capsule will now be locked and secured. 
2.2  Output Connections 
The main DC output terminal is a screw type terminal located in the rear panel. Figure 5 below 
illustrates the size and dimensions of the terminal. To loosen, use hex key #4 size screwdriver. 
Note: The screws on the terminals can be completely removed to allow for ring type adapters 
(must be greater than 6mm in diameter). 
Due to the high current rating of the power supply, proper wire sizes are necessary for safe 
connectivity and to prevent wires from overheating. Refer to the below table as a reference for 
proper wire sizes according to the amount of current used for operation: 
Table 1 - Wire Gauge Rating 
AWG 
6 
8 
10 
12 
14 
16 
18 
20 
22 
Imax(A) 
75 
55 
40 
25 
20 
13 
10 
7 
5 
mΩ/meter 
1.3 
2.1 
3.3 
5.2 
8.3 
13.2 
21 
33.5 
52.8 
10mm 
10mm 
Rear Output Terminal 
10mm 
6mm 
Hex Key Screw 