Instruction manual

onlinecomponents.com
4080 series Function & Arbitrary/Function Generators Instruction Manual
44
Set phase 1 of PSK in 0--360º.
PSKey:PHASe1
Check phase 1of PSK
PSKey:PHASe2 <degrees>
Set phase 2 of PSK in 0--360º.
PSKey:PHASe2
Check phase 2 of PSK.
PSKey:INTernal:SPACe <time>
Set time interval of phase switching
PSKey:INTernal:SPACe?
Check time interval of phase switching
PSKey: SOURce {INTernal|EXTernal}
Set trigger source of PSK as internal (INTernal) or external (EXTernal).
PSKey:SOURce
Check current trigger source of PSK.
PSKey:STATe {ON|OFF}
Turn on PSK mode (ON) or turn of f PSK mode (OFF).
PSKey:STATe
Check the “on/off” state of PSK mode. The returned data are “0” (OFF) or “1” (ON). It returns to
fixed frequency mode in “off” state.
Sweep Mode instructions
1. To set the output waveform, amplitude, DC offset and frequency using APPLy instructions or
FUNCtion, FREQuency, VOLTage, VOLTAGE:OFFSet instructions.
2. To set start frequency of sweep using FREQuency: STARt <frequency> instruction.
3. To set stop frequency of sweep using P FREQuency: STOP<frequency> instruction.
4. To set sweep mode using SWEep: SPACing {LINear|LOGarithmic} instruction.
5. To set sweep time using SWEep: TIME <time> instructions.
6. To set trigger source of sweep using SWEep: SOURce {INTernal|EXTernal}instructions.
7. To turn on sweep using SWEep: STATe ON instruction.
FREQuency:STARt <frequency>
Set start frequency of sweep.
FREQuency:STARt
Check startting frequency of sweep.
FREQuency:STOP <frequency>
Set stop frequency of sweep.
FREQuency:STOP
Check stop frequency of sweep.
SWEep:SPACing {LINear|LOGarithmic}
Set sweep mode as linear (LINear) or logarithmic (LOGarithmic)
SWEep:SPACing
Check sweep mode.