Instruction manual
onlinecomponents.com
4080 series Function & Arbitrary/Function Generators –Instruction Manual 
36
APPLy:SINusoid [<frequency>, <amplitude>, <offset>] 
APPLy:SQUare [<frequency>, <amplitude>, <offset>] 
APPLy:TRIangle [<frequency>, <amplitude>, <offset>] 
APPLy:UP_RAMP [<frequency>, <amplitude>, <offset>] 
APPLy:DOWN_RAMP [<frequency>, <amplitude>, <offset>] 
APPLy:NOISe [<frequency>*, <amplitude>, <offset>] 
APPLy:P_DC [<frequency>,* <amplitude>, <offset>]  
APPLy? 
*: if waveform is Noise or DC, the frequency data contained in the command is not invalid. 
[SOURce:] 
FUNCtion  SHAPe {SINusoid|SQUare|TRIangle|UP_RAMP|DOWN_RAMP| 
NOISe|PULSe|P_PULSE|N_PULSE|P_DC|N_DC|STAIR| 
C_PULSE|COMMUT_FU|COMMUT_HA|SINE_TRA| 
SINE_VER|SINE_PM|LOG|EXP|ROUND_HAL| 
SINX/X|SQU_ROOT|TANGent|CARDIO|QUAKE|COMBIN} 
FUNCtion:SHAPe? 
[SOURce:] 
FREQuency <frequency> 
FREQuency? 
[SOURce:] 
PULSe:DCYCle <percent> 
PULSe:DCYCle? 
[SOURce:] 
VOLTage <amplitude> 
VOLTage? 
VOLTage: OFFSet <offset> 
VOLTage: OFFSet? 
[SOURce:] 
OUTPut:LOAD {50|INFinity} 
OUTPut:LOAD? 
INPUT:FILTER <on|off> 
INPUT:FILTER? 
INPUT:ATTenuator <on|off> 
INPUT:ATTenuator? 
*SAV {0|1|2|3|4|5|6|7|8|9|10}. State 0 is the working state of the instrument before power off 
*RCL {0|1|2|3|4|5|6|7|8|9|10}. States 1—10 are user defined working states 
RF:STATe <ON/OFF> 
RF:STATe? 
[SOURce:] 
MODULATION instructions 
OUTPUT instructions 