User Manual
7
Lubrication:
No additional lubrication is necessary. The shaft seal and bearings are fully lubricated
from the factory. Seal oil should be checked once per year. See table below.
OIL FILL QUANTITY/TYPE
OIL IN SEAL CHAMBER
MODEL
U.S. FL. OZ.
CC.
TYPE OF OIL
S750C
7.8
230
ISO 32 NSF Food Grade Mineral Oil
S750C-3
7.8
230
ISO 32 NSF Food Grade Mineral Oil
S1500C
7.8
230
ISO 32 NSF Food Grade Mineral Oil
S08C
7.8
230
ISO 32 NSF Food Grade Mineral Oil
S08C-3
7.8
230
ISO 32 NSF Food Grade Mineral Oil
S15C
7.8
230
ISO 32 NSF Food Grade Mineral Oil
S22C
11.8
350
ISO 32 NSF Food Grade Mineral Oil
S37C
11.8
350
ISO 32 NSF Food Grade Mineral Oil
S55C
35.5
1050
ISO 32 NSF Food Grade Mineral Oil
S75C
35.5
1050
ISO 32 NSF Food Grade Mineral Oil
OIL IN SEAL CHAMBER
MODEL
U.S. FL. OZ.
CC.
TYPE OF OIL
SX750CSS
10.1
300
ISO 32 NSF Food Grade Mineral Oil
SX750CSS-3
10.1
300
ISO 32 NSF Food Grade Mineral Oil
SX1500CSS
10.1
300
ISO 32 NSF Food Grade Mineral Oil
SX08CSS
10.1
300
ISO 32 NSF Food Grade Mineral Oil
SX08CSS-3
10.1
300
ISO 32 NSF Food Grade Mineral Oil
SX15CSS
10.1
300
ISO 32 NSF Food Grade Mineral Oil
SX22CSS
13.5
400
ISO 32 NSF Food Grade Mineral Oil
SX37CSS
13.5
400
ISO 32 NSF Food Grade Mineral Oil
SX55CSS
35.5
1050
ISO 32 NSF Food Grade Mineral Oil
SX75CSS
35.5
1050
ISO 32 NSF Food Grade Mineral Oil
PUMP INSTALLATION
S & SX Series pumps have been evaluated for use with water or water based solutions.
Please contact the manufacturer for additional information.
Risk of electric shock. Pump models; S750C, SX750C, S750C-3,
SX750CSS (115v) are supplied with a grounding conductor and grounding-type
attachment plug. 230V single phase pumps and all three phase pumps do not come
with electric plug connectors. To reduce the risk of electric shock, be certain that it is