Product specifications

SRP-350/352plusII
Rev. 1.01 BIXOLON
- 62 -
<Function 1> GS ( E pL pH fn d1 d2 (fn=1)
Code:
ASCII
GS
(
E
pL
pH
fn
d1
d2
Hex
1D
28
45
pL
pH
fn
d1
d2
Decimal
29
40
69
pL
pH
fn
d1
d2
Range:
(pL + pH x 256) = 1 (pL=1, pH=0)
fn=1
d1=73, d2=78
Default:
None
Description:
This command starts the user setting mode, enabling the printer to notify that the mode has changed as follows:
[Mode change feedback]
Hexadecimal
Decimal
Number of Data
Header
37H
55
1 byte
Flag
20H
32
1 byte
NUL
00H
0
1 byte
Remarks:
This command is effective only in standard mode, not in page mode.
Upon entering the user mode setting mode by this command, the printer transmits “mode change feedback” to the
host.
The user setting mode should be enabled prior to processing <Function 2> through 12. Otherwise, those functions
are ignored.
After confirming “mode change feedback”, it is recommended to send the command to reconfigure the NV user
memory.
Differences: