Product specifications
SRP-350/352plusII
Rev. 1.01 BIXOLON
- 62 -
<Function 1> GS ( E pL pH fn d1 d2 (fn=1)
Code:
ASCII
GS
(
E
pL
pH
fn
d1
d2
Hex
1D
28
45
pL
pH
fn
d1
d2
Decimal
29
40
69
pL
pH
fn
d1
d2
Range:
(pL + pH x 256) = 1 (pL=1, pH=0)
fn=1
d1=73, d2=78
Default:
None
Description:
This command starts the user setting mode, enabling the printer to notify that the mode has changed as follows:
[Mode change feedback]
Hexadecimal
Decimal
Number of Data
Header
37H
55
1 byte
Flag
20H
32
1 byte
NUL
00H
0
1 byte
Remarks:
■ This command is effective only in standard mode, not in page mode.
■ Upon entering the user mode setting mode by this command, the printer transmits “mode change feedback” to the
host.
■ The user setting mode should be enabled prior to processing <Function 2> through 12. Otherwise, those functions
are ignored.
■ After confirming “mode change feedback”, it is recommended to send the command to reconfigure the NV user
memory.
Differences:
None