QRCODE Symbol Data (cn = 49)
The symbol data is defined, stored to the symbol storage area by Function 180 and printed by the specification of
Function 181. The symbol data in the area remains reserved until the following processes are executed:
Performing Function 180
Performing ESC @
Performing the printer reset and power-off
The setting values of Functions 165 to 169 are utilized for the processing of Function 180 or 182. The printable area
must be large enough to accommodate different-size symbols. If not, the symbol may not be printed.
The same symbol data is repeatedly printed by executing Function 181 after performing Function 180.
The same symbol data is printed differently by executing Function 181 after setting the feature of the symbol by using
Functions 165 through 169.
By using Function 182, the symbol size printed by Function 181 is available.
Differences: