Specifications

SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 136 -
GS w
Function: Set bar code width
Code:
ASCII
GS w n
Hex
1D 77 n
Decimal
29 119 n
Range:
2 n 6
Default:
n=3
Description:
This command sets the horizontal size of the bar code, using n as follows:
Binary-level bar code
n
Multi-level bar code module
width (mm)
Thin element width (mm) Thick element width (mm)
2
0.250 0.250 0.625
3
0.375 0.375 1.000
4
0.500 0.500 1.250
5
0.625 0.625 1.625
6
0.750 0.750 2.000
n specifies the bar code module width.
Remarks:
The setting of this command is effective for the following bar codes:
Multi-level bar codes (UPC-A, UPC-E, JAN13, HAN8, CODE93, CODE128)
Binary-level bar codes (CODE39, ITF, CODABAR)
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
None