Specifications
SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 126 -
■ The printer information transmitted is comprised of 4 bytes as follows:
• First byte(printer information)
Bit Off/On Hex Decimal Function
0 Off 00 0 Not used. Fixed to Off
1 Off 00 0 Not used. Fixed to Off
2 Off 00 0 Not used. Fixed to Off
Off 00 0 On-line
3
On 08 8 Off-line
4 On 10 16 Not used. Fixed to On
Off 00 0 Cover is close
5
On 20 32 Cover is open
Off 00 0 Paper is not being fed by the paper feed button
6
On 40 64 Paper is being fed by the paper feed butto
7 Off 00 0 Not used. Fixed to Off
• Second byte(printer information)
Bit Off/On Hex Decimal Function
0 Off 00 0 Not used. Fixed to Off
1 Off 00 0 Not used. Fixed to Off
2 Off 00 0 Not used. Fixed to Off
3 Off 00 0 Not used. Fixed to Off
4 Off 00 0 Not used. Fixed to Off
Off 00 0 No unrecoverable error
5
On 20 32 Unrecoverable error
Off 00 0 No automatically recoverable error
6
On 40 64 Automatically recoverable error occurred
7 Off 00 0 Not used. Fixed to Off
- If mechanical error (bit 2) or auto-cutter error (bit 3) occurs due to paper jams or the like, it is possible to recover
by correcting a cause of the error and executing ENQ in real time mode.
- If an unrecoverable error (bit 5) occurs, turn off the power as soon as possible.