Specifications

SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 119 -
GS I b
Function: Transmits battery status
Code:
ASCII
GS I b
Hex
1D 49 62
Decimal
29 73 98
Range:
None
Default:
None
Description:
This command transmits the battery power status of the printer.
The printer transmits [Header ~ NUL] data as shown below:
Transmitted data Hex Decimal Amount of data
Header 37H 55 1byte
Identifier 45H 69 1byte
Remaining battery power 30h-34H 48-52 1byte
NUL 00H 0 1byte
“Remaining battery power“ is indicated as following:
Hex Decimal Remaining battery power level
30H 48 Full(F)
31H 49 High(H)
32H 50 Middle(M)
33H 51 Low(L)
Remarks:
The remaining battery amount can be examined by the battery LED.
When the remaining battery power reaches Low level, the red LED of battery starts blinking as an alert signal.
This command can be executed in real-time command mode using DLE.
Differences:
None