Specifications
SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 119 -
GS I b
Function: Transmits battery status
Code:
ASCII
GS I b
Hex
1D 49 62
Decimal
29 73 98
Range:
None
Default:
None
Description:
■ This command transmits the battery power status of the printer.
• The printer transmits [Header ~ NUL] data as shown below:
Transmitted data Hex Decimal Amount of data
Header 37H 55 1byte
Identifier 45H 69 1byte
Remaining battery power 30h-34H 48-52 1byte
NUL 00H 0 1byte
• “Remaining battery power“ is indicated as following:
Hex Decimal Remaining battery power level
30H 48 Full(F)
31H 49 High(H)
32H 50 Middle(M)
33H 51 Low(L)
Remarks:
■ The remaining battery amount can be examined by the battery LED.
■ When the remaining battery power reaches Low level, the red LED of battery starts blinking as an alert signal.
■ This command can be executed in real-time command mode using DLE.
Differences:
None