Product specifications

SPP-R210 Command Manual
Rev. 1.00 BIXOLON
- 97 -
<Function 281> GS ( k pL pH cn fn m (fn=81)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
m
Hex
1D
28
6B
03
00
32
51
m
Decimal
29
40
107
3
0
50
81
m
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=50
fn=81
m=48
Default:
None
Description:
This command encodes and prints Maxi Code symbol data saved in the storage area.
Remarks:
In standard mode, this command is available only when printer is at the beginning of a line or the printer buffer is
empty.
A symbol exceeding the printing area in size can not be printed.
Printing operation is not processed under the following conditions:
There is no data. (Function 280 is not executed)
The number of numeric characters exceeds 138
The number of alphanumeric characters exceeds 93
When mode 2 is selected, the primary message does not include all of the following:
Primary Message
Data Number
Character
Postal code
1~9
Numeric
ISO country code
1~3
Numeric
Service type code
1~3
Numeric
When mode 3 is selected, the primary message does not include all of the following:
Primary Message
Data Number
Character
Postal code
1~6
Setting Code A
ISO country code
1~3
Numeric
Service type code
1~3
Numeric