<Function 180> GS ( k pL pH cn fn m d1...dk (fn=80)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
m
d1...dk
Hex
1D
28
6B
pL
pH
31
50
30
d1...dk
Decimal
29
40
107
pL
pH
49
80
48
d1...dk
Range:
4 ≤ (pL + pH x 256) ≤7092 (0 ≤ pL255, 0 ≤ pH ≤ 27)
cn=49
fn=80
m=48
0 ≤ d ≤ 255
k = (pL + pH x 256) 3
Default:
None
Description:
This command saves symbol data of the QR Code to the symbol storage area.
Remarks:
The symbol data is defined, stored to the symbol storage area by Function 180 and printed by the specification of
Function 181. The data remains reserved after completion of printing.
The following shows the data available for encoding of QR code.
Character Type
Usable Characters
Numeric Data
“0” ~ “9”
Alphanumeric Data
“0” ~ “9”, “A” ~ “Z”, SP, $, %, *, +, -, ., /, :
Kanji Data
Shift JIS value
8bit Byte Data
00H ~ FFH
The setting of this command remains effective until the following processing is performed:
Performing Function 180
Performing ESC @
Performing the printer reset or power-off
Differences: