<Function 112> GS ( F pL pH m aL aH bL bH (m=112)
Code:
ASCII
GS
(
F
pL
pH
m
aL
aH
bL
bH
Hex
1D
28
46
05
00
70
aL
aH
bL
bH
Decimal
29
40
70
5
0
112
aL
aH
bL
bH
Range:
(pL + pH × 256) = 5 (pL = 5, pH = 0)
m = 112
0 ≤ (aL + aH × 256) ≤ 65535 (0 ≤ aL ≤ 255, 0 ≤ aH ≤ 255)
0 ≤ (bL + bH × 256) ≤ 65535 (0 ≤ bL ≤ 255, 0 ≤ bH ≤ 255)
Default:
aL = 141, aH = 0 (BM height(top of a BM ~ bottom of BM): 20 mm)
bL = 20, bH = 11 (BM interval(top of a BM ~ top of next BM): 400 mm)
Description:
This command sets the black mark paper format.
pL, pH specifies (pL + pH × 256) as the number of bytes after pH (m, aL, aH,bL, bH).
aL, aH specifies [(aL + aH × 256) × vertical motion units] as the BM height.
bL, bH specifies as [(bL + bH × 256) × vertical motion units] as the BM interval.
Remarks:
The available BM height ranges from 4 to 20 mm.
If the BM height specified is out of range, this command is ignored.
The BM interval ranges from 40 to 400 mm.
If the BM interval specified is out of range, this command is ignored.
Differences: