Product specifications
SPP-R210 Command Manual
Rev. 1.00 BIXOLON
- 32 -
ESC @
Function:
Initialize printer
Code:
ASCII
ESC
@
Hex
1B
40
Decimal
27
64
Range:
None
Default:
None
Description:
This command cancels conditions previously set and initializes the printer to the conditions having existed at power on.
Remarks:
■ The data in the printer buffer is cleared.
■ The settings of DIP switch are not re-read.
■ The data in the receive buffer is not discarded.
■ All of the settings such as print mode and line feed are cleared.
■ NV graphics and NV user memory are not cleared.
■ In page mode, this command removes the data in print areas, restores the initial settings and returns to standard
mode.
Differences:
None