Product specifications

SPP-R210 Command Manual
Rev. 1.00 BIXOLON
- 32 -
ESC @
Function:
Initialize printer
Code:
ASCII
ESC
@
Hex
1B
40
Decimal
27
64
Range:
None
Default:
None
Description:
This command cancels conditions previously set and initializes the printer to the conditions having existed at power on.
Remarks:
The data in the printer buffer is cleared.
The settings of DIP switch are not re-read.
The data in the receive buffer is not discarded.
All of the settings such as print mode and line feed are cleared.
NV graphics and NV user memory are not cleared.
In page mode, this command removes the data in print areas, restores the initial settings and returns to standard
mode.
Differences:
None