Product specifications
SPP-R210 Command Manual
Rev. 1.00 BIXOLON
- 18 -
ESC SP
Function:
Set the character right space
Code:
ASCII
ESC
SP
n
Hex
1B
20
n
Decimal
27
32
n
Range:
0 ≤ n ≤ 255
Default:
n=0
Description:
■ This command sets the size of space to right of character.
• Right space = n × [horizontal motion units].
Remarks:
■ In a double width mode, the right space will be doubled.
■ Horizontal motion unit varies depending the printer model.
Differences:
Example:
■ Horizontal motion unit: 0.125mm(1/203 inch)
■ Input:
0x1b 0x20 0x20
0x31 0x32 0x33 0x0a
0x1b 0x20 0x40
0x31 0x32 0x33 0x0a
0x1b 0x20 0x60
0x31 0x32 0x33 0x0a