Product specifications

SPP-R210 Command Manual
Rev. 1.00 BIXOLON
- 174 -
BS M S PL PH fn4 m
Function
Transmit Start and End characters setting information
Code:
ASCII
BS
M
S
pL
pH
fn4
m
Hex
08
4D
53
pL
pH
34
m
Decimal
08
77
83
pL
pH
52
m
Range:
(pL+pHx256) = 2
fn = 50
m = 49, 50, 51
Default:
None
Description:
m defines the track to be transmitted.
The transmission format is as follows:
Hexadecimal
Decimal
Amount of Data
Header
37H
55
1 byte
Flag
81H
129
1 byte
Track
31H~33H
49~51
1byte
Start characters
20H ~ 7FH
32~127
Max 10 bytes
Separate
1F
31
1byte
End characters
20H~7FH
32~127
Max 10 bytes
NUL
00H
0
1 byte
The track on the above table indicates the track information of transmission data.
For example, the track value of 31H indicates the information on the Start and End characters of Track 1.
If d is set to Null 1-byte in fn3, End characters are not transmitted.
Remarks:
None