BS M S PL PH fn2 m d1~dk
Function
Set start sentinel characters
Code:
ASCII
BS
M
S
pL
pH
fn2
m
d1~dk
Hex
08
4D
53
pL
pH
32
m
d1~dk
Decimal
08
77
83
pL
pH
50
m
d1~dk
Range:
3 ≤ (pL+pHx256) ≤ 12
m = 49, 50, 51 32 ≤d ≤127, k ≤ 10
fn = 50
Default:
Track 1 : “START1 “
Track 2 : “START2 “
Track 3 : “START3 “
Description:
■ m defines the track to set Start characters.
■ d indicates the characters to be set as Start characters.
■ k indicates the number of characters to be used as Start characters.
■ k is defined as (PL + PH x 256) – 2.
■ If Multi-byte sentinel characters mode is set by fn1 after setting Start
characters, the Start characters are added to the beginning parts of each.
track data after reading card data and then the card data is transmitted.
■ The specified Start characters are saved to non-volatile memory so the
setting value is not changed even though the printer is reset.
Remarks:
None