Product specifications
SPP-R210 Command Manual
Rev. 1.00 BIXOLON
- 152 -
GS h
Function:
Selects bar code height
Code:
ASCII
GS
h
n
Hex
1D
68
n
Decimal
29
104
n
Range:
1 ≤ n ≤ 255
Default:
n=162
Description:
This command sets the height of the bar code to n dots.
Remarks:
■ The unit of n depends on the printer model.
■ The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
Example:
■ Unit of one dot: 0.125mm(1/203 inch)
■ Input:
0x1d 0x68 0x40
0x1d 0x6b 0x49 0x0a 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30
0x0a
0x1d 0x68 0x80
0x1d 0x6b 0x49 0x0a 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30
0x0a
0x1d 0x68 0xc0
0x1d 0x6b 0x49 0x0a 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30
0x0a