Product specifications

SPP-R210 Command Manual
Rev. 1.00 BIXOLON
- 137 -
GS I b
Function:
Transmits battery status
Code:
ASCII
GS
I
b
Hex
1D
49
62
Decimal
29
73
98
Range:
None
Default:
None
Description:
This command transmits the battery power status of the printer.
The printer transmits [Header ~ NUL] data as shown below:
Transmitted data
Hex
Decimal
Amount of data
Header
37H
55
1byte
Identifier
45H
69
1byte
Remaining battery power
30h-34H
48-52
1byte
NUL
00H
0
1byte
“Remaining battery power“ is indicated as following:
Hex
Decimal
Remaining battery power level
30H
48
Full(F)
31H
49
High(H)
32H
50
Middle(M)
33H
51
Low(L)
Remarks:
The remaining battery amount can be examined by the battery LED.
When the remaining battery power reaches Low level, the red LED of battery starts blinking as an alert signal.
This command can be executed in real-time command mode using DLE.
Differences: