Product specifications

SPP-R210 Command Manual
Rev. 1.00 BIXOLON
- 115 -
<Function 580> GS ( k pL pH cn fn m d1…dk (fn=80)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
m
d1...dk
Hex
1D
28
6B
pL
pH
35
50
30
d1...dk
Decimal
29
40
107
pL
pH
53
80
48
d1...dk
Range:
0 (pL + pH x 256) 3803 (0 ≤ pL255, 0 ≤ pH ≤ 14)
cn=53
fn=80
m=48
0 d 255
k = (pL + pH x 256) - 3
Default:
None
Description:
Store Aztec barcode symbol data in the symbol storage area.
Remarks:
The data stored to the symbol storage area by this command is executed by Function 581. The data remains
reserved in the symbol storage area.
Digits only : maximum capacity 3800 digits.
Alphanumeric text : maximum capacity 300 characters.
Byte values : maximum capacity 1900 bytes.
Differences:
None