<Function 566> GS ( k pL pH cn fn n (fn=66)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
34
46
n
Decimal
29
40
107
3
0
52
70
n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=53
fn=66
48 ≤ n ≤ 51
Default:
n=49
Description:
Sets the error correction level of the AZTEC code
n
Function
Recovery Amount (%)
48
Error Correction Level L
10
49
Error Correction Level M
23
50
Error Correction Level Q
36
51
Error Correction Level H
50
■ The setting of this function impacts the execution of <Function 581>.
■ This function is effective until ESC @ is executed or the printer power is turned off.