SPP-R210 Command Manual Rev. 1.00 http://www.bixolon.
SPP-R210 Command Manual ■ Contents 1. Notice ........................................................................................................................................................................................................ 3 2. SPP-R210 Supported Commands........................................................................................................................................................... 4 2-1 Command Description Items ............................................
SPP-R210 Command Manual 1. Notice This document contains proprietary information of BIXOLON Corporation and its affiliates. You may utilize the information solely for the purpose of facilitating authorized sales and service of, or developing software and similar products for authorized use with, BIXOLON products, provided that such proprietary information may not be used, reproduced, or disclosed to any other parties for any other purpose without the prior written permission of BIXOLON Corporation.
SPP-R210 Command Manual 2. SPP-R210 Supported Commands No. 1 2 3 4 5 6 7 Command EOT HT LF FF CR DLE CAN Function Transmit status Horizontal tab Print and line feed Form feed (in page mode) Print and carriage return Set real-time command mode Cancel the print data in page mode No.
SPP-R210 Command Manual 2-1 Command Description Items Command Function: Command function outline Code: Command format expressed in ASCII, hexadecimal, and decimal codes Range: Argument value (Setting range) for the command Default: Initial argument value for the command Description: Detailed command function description Remarks: Additional information about using the command Differences: Variations depending on the printer model Example: Refer to example command code Rev. 1.
SPP-R210 Command Manual 2-2 Details of Control Commands EOT Function: Code: Transmit status ASCII Hex Decimal Range: 1≤n≤4 Default: None EOT 04 4 n n n Description: This command transmits the printer-related status specified by n as follows: n Function 1 Transmit printer status 2 Transmit off-line status 3 Transmit error status 4 Transmit paper roll sensor status ■ Printer transmits the following status n=1: Printer status Bit 0 1 2 3 4 5 6 7 Rev. 1.
SPP-R210 Command Manual n=2: Off-line status Bit 0 1 2 3 4 5 6 7 Off/On Off On Off On Off On On Off On Off Off Hex 00 02 00 04 00 08 10 00 20 00 00 Decimal 0 2 0 4 0 8 16 0 32 0 0 Status Fixed Fixed Cover is closed Cover is open Paper is not being fed by using the paper FEED button Paper is being fed by the paper FEED button Fixed No paper-end stop Printing is being stopped Fixed Fixed n=3: Error status Bit 0 1 2 3 4 5 6 7 Rev. 1.
SPP-R210 Command Manual n=4: paper sensor status Bit 0 1 2 3 4 5,6 7 Remarks: ■ ■ Binary 0 1 0 0 1 00 11 0 Hex 00 02 00 00 10 00 60 00 Decimal 0 2 0 0 16 0 96 0 Status Not used. Fixed to Off Not used. Fixed to On Not used. Fixed to Off Not used. Fixed to Off Not used. Fixed to On Paper end sensor: paper present Paper end sensor: paper not present Not used. Fixed to Off This command can be executed in a real time mode using DLE.
SPP-R210 Command Manual HT Function: Code: Horizontal tab ASCII Hex Decimal HT 09 9 Range: None Default: None Description: This command moves the print position to the next horizontal tab position. If the next horizontal tab position is not specified, this command will be void. Remarks: ■ Differences: None Example: ■ The horizontal tab position is set by D. ■ With the underline mode turned on, the underline printing is not applied to the tab space created by this command.
SPP-R210 Command Manual LF Function: Code: Print and line feed ASCII Hex Decimal LF 0A 10 Range: None Default: None Description: This command prints the data in the print buffer and feeds one line based on the current set line spacing in standard mode. Remarks: ■ Differences: None Example: ■ Rev. 1.00 In page mode, the printer does not perform actual printing, but moving only the print position to the next line.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual FF Function: Code: Form feed (in page mode) ASCII Hex Decimal FF 0C 12 Range: None Default: None Description: This commands prints all data collected in the printer buffer In page mode. After completion of printing, the printer is returned to standard mode. Remarks: ■ ■ Differences: None Example: ■ Rev. 1.00 The printer is returned to standard mode after completion of printing.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual CR Function: Code: Print and carriage return ASCII Hex Decimal CR 0D 13 Range: None Default: None Description: This command prints the data. With auto line feed enabled, it performs printing and one line feeding same as LF. Remarks: ■ Differences: None Rev. 1.00 Auto line feed is only enabled with a parallel interface using the DIP switch.
SPP-R210 Command Manual DLE Function: Code: Set real-time command mode ASCII Hex Decimal DLE 10 16 Range: None Default: None Description: This command enables commands to be operable in real-time. Remarks: ■ ■ ■ Differences: ■ Rev. 1.00 A single command following this command is regarded as a real time command. The real time command is stored into the receive buffer and executed with higher priority than other commands.
SPP-R210 Command Manual CAN Function: Code: Cancel the print data in page mode ASCII Hex Decimal CAN 18 24 Range: None Default: None Description: This command clears the receive buffer and print buffers in page mode. Remarks: ■ Differences: None Example: ■ Rev. 1.00 This command is effective only in page mode that is set by ESC L.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual ESC SP Function: Set the character right space Code: ASCII Hex Decimal Range: 0 ≤ n ≤ 255 Default: n=0 Description: ■ This command sets the size of space to right of character. • Right space = n × [horizontal motion units]. Remarks: ■ ■ In a double width mode, the right space will be doubled. Horizontal motion unit varies depending the printer model. Differences: ■ Horizontal motion unit: 0.125mm(1/203 inch) Example: ■ Rev. 1.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual ESC ! Function: Set print mode Code: ASCII Hex Decimal Range: 0 ≤ n ≤ 255 Default: n=0 Description: This command selects print mode(s) with bits having following meanings.
SPP-R210 Command Manual Example: Input : 0x1b 0x21 0x00 0x46 0x6f 0x6e 0x74 0x41 0x0a 0x1b 0x21 0x01 0x46 0x6f 0x6e 0x74 0x42 0x0a 0x1b 0x21 0x08 0x45 0x6d 0x70 0x68 0x61 0x73 0x69 0x7a 0x65 0x64 0x20 0x6d 0x6f 0x64 0x65 0x0a 0x1b 0x21 0x30 0x44 0x6f 0x75 0x62 0x6c 0x65 0x20 0x73 0x69 0x7a 0x65 0x0a 0x1b 0x21 0x80 0x55 0x6e 0x64 0x65 0x72 0x6c 0x69 0x6e 0x65 0x20 0x6d 0x6f 0x64 0x65 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual ESC $ Function: Code: Set absolute print position ASCII Hex Decimal ESC 1B 27 $ 24 36 nL nL nL nH nH nH Range: 0 ≤ (nL + nH x 256) ≤ 65535 (0 ≤ nH ≤ 255, 0 ≤ nL ≤ 255) Default: None Description: This command specifies the next print starting position in reference to the left edge of the print area. The printing start position is calculated using (nL + nH x 256) x (vertical or horizontal motion units). Remarks: ■ ■ ■ Differences: ■ Example: ■ Rev. 1.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual ESC * Function: Code: Specify bit image mode ASCII Hex Decimal ESC 1B 27 * 2A 42 m m m nL nL nL nH nH nH Range: m = 0, 1, 32, 33 0 ≤ nL ≤ 255 0 ≤ nH ≤ 3 0 ≤ d ≤ 255 k = nL + nH × 256 [in case of m = 0, 1] k = (nL + nH × 256) × 3 [in case of m = 32, 33] Default: None d1...dk d1...dk d1...dk Description: ■ This command specifies the bit image for the mode m as to the number of dots specified by nL and nH.
SPP-R210 Command Manual Example: Input: 0x1b 0x2a 0x00 0x0f 0x00 0x01 0x02 0x04 0x08 0x10 0x20 0x40 0x80 0x40 0x20 0x10 0x08 0x04 0x02 0x01 0x0a 0x1b 0x2a 0x01 0x0f 0x00 0x01 0x02 0x04 0x08 0x10 0x20 0x40 0x80 0x40 0x20 0x10 0x08 0x04 0x02 0x01 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual ESC – Function: Code: Turn underline mode on/off ASCII Hex Decimal ESC 1B 27 Range: 0 ≤ n ≤ 2, 48 ≤ n ≤ 50 Default: n=0 Description: ■ Remarks: ■ Differences: None Rev. 1.00 2D 45 n n n This command enables the print data following it to be printer out underlined.
SPP-R210 Command Manual Example: Input: 0x1b 0x2d 0x00 0x54 0x45 0x53 0x54 0x30 0x30 0x0a 0x0a 0x1b 0x2d 0x01 0x54 0x45 0x53 0x54 0x30 0x31 0x0a 0x0a 0x1b 0x2d 0x02 0x54 0x45 0x53 0x54 0x30 0x32 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual ESC 2 Function: Code: Select default line spacing ASCII Hex Decimal ESC 1B 27 2 32 50 Range: None Default: None Description: This command sets the default line spacing The default line spacing is approximately 3.75 mm, which is equivalent to 30 dots. Remarks: ■ Differences: ■ Rev. 1.00 The line spacing can be set independently in standard mode and in page mode.
SPP-R210 Command Manual ESC 3 Function: Set line spacing Code: ASCII Hex Decimal Range: 0 ≤ n ≤ 255 Default: Corresponding to the default line spacing defined by ESC 2 Description: ■ Remarks: ■ ■ Differences: ■ Rev. 1.00 ESC 1B 27 3 33 51 n n n This command sets the line spacing using a following rule. • Line spacing = n x (vertical or horizontal motion units) With standard mode selected, the vertical motion unit is used.
SPP-R210 Command Manual Example: Input: 0x54 0x45 0x53 0x54 0x30 0x30 0x1b 0x33 0x50 0x0a 0x54 0x45 0x53 0x54 0x30 0x31 0x1b 0x33 0xa0 0x0a 0x54 0x45 0x53 0x54 0x30 0x32 0x1b 0x33 0xff 0x0a 0x54 0x45 0x53 0x54 0x30 0x33 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual ESC = Function: Code: Select peripheral device ASCII Hex Decimal ESC 1B 27 = 3D 61 n n n Range: 1≤n≤3 Default: n =1 Description: ■ The selection of peripherals according to the n value is as follows. n Function 1,3 Printer Activation 2 Printer Deactivation Remarks: ■ When the printer is deactivated, all received data is not recognized, but “ESC =” and real-time commands are recognized. Differences: None Rev. 1.
SPP-R210 Command Manual ESC @ Function: Code: Initialize printer ASCII Hex Decimal ESC 1B 27 @ 40 64 Range: None Default: None Description: This command cancels conditions previously set and initializes the printer to the conditions having existed at power on. Remarks: ■ ■ ■ ■ ■ The data in the printer buffer is cleared. The settings of DIP switch are not re-read. The data in the receive buffer is not discarded. All of the settings such as print mode and line feed are cleared.
SPP-R210 Command Manual ESC D Function: Code: Set horizontal tab position ASCII Hex Decimal ESC 1B 27 D 44 68 n1...nk n1...nk n1...nk Range: 1 ≤ n ≤ 255 , 0 ≤ k ≤ 32 Default: n=8, 16, 24, 32, 40,....., 232, 240, 248 Description: ■ Remarks: ■ ■ ■ ■ Differences: None Rev. 1.00 NUL 00 0 This command sets the horizontal tab position. • n defines the number of columns from the beginning of the line to the horizontal tab setting. • k denotes the number of horizontal tab positions to be set.
SPP-R210 Command Manual Example: Input: 0x48 0x09 0x48 0x09 0x48 0x09 0x48 0x0a 0x1b 0x44 0x0a 0x14 0x1e 0x00 0x48 0x09 0x48 0x09 0x48 0x09 0x48 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual ESC E Function: Turn emphasized mode on / off Code: ASCII Hex Decimal Range: 0 ≤ n ≤ 255 Default: n=0 Description: ■ This command turns emphasized mode on or off by toggling the least significant bit of n like following. • When the LSB of n is 0, emphasized mode is turned off. • When the LSB of n is 1, emphasized mode is turned on. Remarks: ■ The setting of this command remains effective until ESC !, ESC @, printer reset or power cycling is executed.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual ESC G Function: Turn double-strike mode on/off Code: ASCII Hex Decimal Range: 0 ≤ n ≤ 255 Default: n=0 Description: ■ This command turns double-strike mode on or off by toggling the least significant bit of n like following. • When the LSB of n is 0, emphasized mode is turned off. • When the LSB of n is 1, emphasized mode is turned on. Remarks: ■ The setting of this command remains effective until ESC !, ESC @, printer reset or power cycling is executed.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual ESC J Function: Print and feed paper Code: ASCII Hex Decimal Range: 0 ≤ n ≤ 255 Default: None Description: This command prints the data in the print buffer and feeds the paper [n X vertical motion unit]. Remarks: ■ ■ ■ Differences: ■ Example: Rev. 1.00 ESC 1B 27 J 4A 74 n n n The maximum feed amount available varies depending on the printer model. With standard mode selected, the vertical motion unit is used.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual ESC L Function: Code: Select page mode ASCII Hex Decimal ESC 1B 27 L 4C 76 Range: None Default: None Description: This command switches from standard mode to page mode. Remarks: ■ ■ ■ ■ ■ ■ Differences: Rev. 1.00 For printing in page mode, ESC T defines the print direction and starting position that is within the print area specified by ESC W. The conditions by the following commands are defined independently in standard mode and page mode.
SPP-R210 Command Manual ESC M Function: Code: Select character font/ MSR card read ASCII Hex Decimal ESC 1B 27 M 4D 77 n n n Range: n = 0,1,2, 48, 49 ,50 ,67, 68, 69, 70, 71, 72, 73 Default: n=0 Description: ▪ Selects only 1byte character fonts ▪ Selects Card reader mode n Function 0, 48 Character font A (12 × 24) selected 1, 49 Character font B (9 × 17) selected 2, 50 Character font C(9 x 24)selected 70 Set 1 track card reader mode 71 Set 2 track card reader mode 72 Set 1,2 track card reader mod
SPP-R210 Command Manual - When set to Track 1 Read mode Normal mode 02H 41H 31H 31H 1CH Max DATA 76 characters (1Track data) 03H 0DH 0AH 1byte sentinel character mode 02H 41H 31H 31H 1CH (Header) 25H (STX) Max DATA 76 characters (1Track data) 3FH (ETX) 03H 0DH 0AH (End) Multi byte sentinel characters mode START characters END characters Max DATA 76 characters (1Track data) 0DH 0AH (Max 10 byte) (Max 10 byte) - When set to Track 2 Read mode Normal mode 02H 42H 31H 31H 1CH Max DATA 37 characters (2Track data
SPP-R210 Command Manual - When set to Track 1/2 Read mode Normal mode Max DATA 76 characters Max DATA 37 Characters 02H 43H 31H 31H 1CH 1CH 1CH 03H 0DH 0AH (1Track data) (2Track data) 1byte sentinel character mode 02H 43H 31H 31H 1CH Max DATA76 Max DATA37 03H 0DH 3BH 3FH 1CH 3BH 3FH 1CH characters Characters 0AH (STX) (ETX) (Separator) (STX) (ETX) (Header) (1Track data) (2Track data) (End) Multi byte sentinel characters mode START characters Max DATA 76 characters END characters 0DH 0AH (Max 10 byte) (1Trac
SPP-R210 Command Manual 1byte sentinel characters mode 02H 46H Max Max Max 03H 31H DATA76 DATA37 DATA104 25H 3FH 1CH 3BH 3FH 1CH 3BH 3FH 0DH 31H characters Characters Characters (STX) (ETX) (Separator) (STX) (ETX) (Separator) (STX) (ETX) 0AH 1CH (1Track (2Track (3Track (End) 1CH data) data) data) (Header) Multi byte sentinel character mode START characters Max DATA 76 characters END characters 0DH 0AH (Max 10 byte) (1Track data) (Max 10 byte) START characters Max DATA 37 characters END characters 0DH 0AH (M
SPP-R210 Command Manual ■ The manual reading of a magnetic card is activated with MSR setting value of 41H that is set by SPP-R210 Unified Utility. In this case, ESC M should be sent to the printer to receive the magnetic card read output prior to swiping the card. In other cases, the printer receives automatically the output whenever the card is read. Remarks: ■ ■ The printer model has it own configuration of Font A and B.
SPP-R210 Command Manual ESC R Function: Code: Specify international character set ASCII Hex Decimal ESC 1B 27 R 52 82 n n n Range: 0≤ n≤10 Default: n=0 Description: This command specifies international characters according to n values. n Character set n Character set 0 U.S.A 7 Spain I 1 France 9 Norway 2 Germany 10 Denmark II 3 U.K 11 Spain II 4 Denmark I 12 Latin America 5 Sweden 13 Korea 6 Italy Remarks: ■ Differences: None Example: ■ Rev. 1.
SPP-R210 Command Manual 0x1b 0x52 0x02 0x23 0x24 0x40 0x5b 0x5c 0x5d 0x5e 0x60 0x7b 0x7c 0x7d 0x7e 0x0a 0x1b 0x52 0x03 0x23 0x24 0x40 0x5b 0x5c 0x5d 0x5e 0x60 0x7b 0x7c 0x7d 0x7e 0x0a 0x1b 0x52 0x04 0x23 0x24 0x40 0x5b 0x5c 0x5d 0x5e 0x60 0x7b 0x7c 0x7d 0x7e 0x0a 0x1b 0x52 0x05 0x23 0x24 0x40 0x5b 0x5c 0x5d 0x5e 0x60 0x7b 0x7c 0x7d 0x7e 0x0a 0x1b 0x52 0x06 0x23 0x24 0x40 0x5b 0x5c 0x5d 0x5e 0x60 0x7b 0x7c 0x7d 0x7e 0x0a 0x1b 0x52 0x07 0x23 0x24 0x40 0x5b 0x5c 0x5d 0x5e 0x60 0x7b 0x7c 0x7d 0x7e 0x0a 0x1b 0x5
SPP-R210 Command Manual 0x23 0x24 0x40 0x5b 0x5c 0x5d 0x5e 0x60 0x7b 0x7c 0x7d 0x7e 0x0a ■ Rev. 1.
SPP-R210 Command Manual ESC S Function: Code: Select standard mode ASCII Hex Decimal ESC 1B 27 S 53 83 Range: None Default: None Description: This command enables standard mode. Remarks: ■ ■ The data in the printer buffer is cleared and the setting by ESC W returns to the default. The conditions by the following commands are defined independently in standard mode and page mode. • ESC SP, ESC 2, ESC 3, ESC U, and FS S ■ In standard mode, CAN, GS $, and GS \ are ignored. Differences: Rev. 1.
SPP-R210 Command Manual ESC T Function: Code: Select print direction in page mode ASCII Hex Decimal ESC 1B 27 T 54 84 n n n Range: 0 ≤ n ≤ 3, 48 ≤ n ≤ 51 Default: n=0 Description: This command selects the print direction and starting position in page mode. n Print Direction Starting Position 0,48 Left right Upper left 1,49 Bottom to top Lower left 2,50 Right left Lower right 3,51 Top bottom Upper right Remarks: ■ ■ Differences: None Rev. 1.
SPP-R210 Command Manual Example: Input: 0x1b 0x4c 0x1b 0x57 0x00 0x00 0x00 0x00 0x80 0x01 0x80 0x01 0x1b 0x54 0x00 0x41 0x42 0x43 0x1b 0x54 0x01 0x41 0x42 0x43 0x1b 0x54 0x02 0x41 0x42 0x43 0x1b 0x54 0x03 0x41 0x42 0x43 0x0c ■ ■ Rev. 1.
SPP-R210 Command Manual ESC W Function: Code: Set print area in page mode ASCII Hex Decimal ESC 1B 27 W 57 87 xL xL xL xH xH xH yL yL yL yH yH yH Range: 0 ≤ (xL + xH x 256) ≤ 65535 (0 ≤ xL ≤ 255, 0 ≤ xH ≤ 255) 0 ≤ (yL + yH x 256) ≤ 65535 (0 ≤ yL ≤ 255, 0 ≤ yH ≤ 255) 1 ≤ (dxL + dxH x 256) ≤ 65535 (0 ≤ dxL ≤ 255, 0 ≤ dxH ≤ 255) 1 ≤ (dyL + dyH x 256) ≤ 65535 (0 ≤ dyL ≤ 255, 0 ≤ dyH ≤ 255) Default: When paper width of 48mm is selected: (xL + xH x 256) = 0 (xL=0, xH=0) (yL + yH x 256) = 0 (yL=0, yH=0
SPP-R210 Command Manual ■ The setting of this command remains effective until ESC !, ESC @, printer reset or power cycling is executed.
SPP-R210 Command Manual ESC \ Function: Code: Set relative print position ASCII Hex Decimal ESC 1B 27 \ 5C 92 nL nL nL nH nH nH Range: 0 ≤ (nL + nH x 256) ≤ 65535 (0 ≤ nL 255, 0 ≤ nH ≤ 255) Default: None Description: ■ Remarks: ■ ■ ■ ■ Differences: None Rev. 1.
SPP-R210 Command Manual Example: Input: 0x41 0x42 0x1b 0x24 0x50 0x00 0x43 0x0a 0x41 0x42 0x1b 0x5c 0x50 0x00 0x43 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual ESC a Function: Code: Set position alignment ASCII Hex Decimal ESC 1B 27 a 61 97 n n n Range: 0 ≤ n ≤2, 48 ≤ n ≤50 Default: n=0 Description: This command specifies position alignment for all data in one line in standard mode, using n as follows: n Alignment 0, 48 Left alignment 1, 49 Center alignment 2, 50 Right alignment Remarks: ■ Differences: None Rev. 1.00 This command is not effective in page mode.
SPP-R210 Command Manual Example: Input: 0x1b 0x61 0x02 0x52 0x49 0x47 0x48 0x54 0x0a 0x1b 0x61 0x01 0x43 0x45 0x4e 0x54 0x45 0x52 0x0a 0x1b 0x61 0x00 0x4c 0x45 0x46 0x54 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual ESC d Function: Print and feed n lines. Code: ASCII Hex Decimal Range: 0 ≤ n ≤ 255 Default: None Description: This command feeds the paper by n lines after printing the data in the print buffer. Remarks: ■ ■ ■ The per-line paper feed amount is based on the value set by the line spacing related commands, ESC 2 and ESC 3. In page mode, this command moves only the print position, not performing actual print.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual ESC t Function: Code: Select character code table ASCII Hex Decimal ESC 1B 27 t 74 116 n n n Range: 0 ≤ n ≤ 5, 16 ≤ n ≤ 19, 21 ≤ n ≤ 31, 33 ≤ n ≤ 41, n=255 Default: For model not supporting Thai character: n=0 For model supporting Thai character support : n = 20 Description: This command specifies code page according to the value of n as follows: n Code page 0 Page 0 437 (USA, Standard Europe) 1 Page 1 Katakana 2 Page 2 850 (Multilingual) 3 Page 3 860 (Portuguese) 4 Page 4
SPP-R210 Command Manual n 26 27 28 29 30 31 33 34 35 36 37 38 39 40 41 42 47 48 255 Remarks: ■ Differences: None Rev. 1.
SPP-R210 Command Manual ESC { Function: Turns upside-down printing mode on/off Code: ASCII Hex Decimal Range: 0 ≤ n ≤ 255 Default: n=0 Description: This command selects/deselects upside-down printing mode according to the least significant bit as follows. LSB Upside-down mode 0 Turned off 1 Turned on Remarks: ■ ESC 1B 27 { 7B 123 n n n This command is valid only when entered at the beginning of the line. ■ The upside-down print mode has no effect in page mode.
SPP-R210 Command Manual Example: Input: 0x41 0x41 0x41 0x41 0x41 0x0a 0x1b 0x7b 0x01 0x41 0x41 0x41 0x41 0x41 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual FS & Function: Code: Select Kanji character mode ASCII Hex Decimal FS 1C 28 & 26 38 Range: None Default: None Description: This command sets Kanji character mode. Remarks: ■ Differences: None Rev. 1.00 This command is available only for the Japanese, Chinese, and Korean models. ■ Kanji codes are comprised of 2 bytes and processed in order of the first and second byte.
SPP-R210 Command Manual FS . Function: Code: Cancel Kanji character mode ASCII Hex Decimal FS 1C 28 . 2E 46 Range: None Default: None Description: This command cancels Kanji character mode. Remarks: ■ Differences: None Rev. 1.00 This command is available only for the Japanese, Chinese, and Korean models. ■ Kanji character mode is enabled using FS &. ■ Once Kanji character mode is canceled, the printer processes a character code as 1-byte code of alphanumeric characters.
SPP-R210 Command Manual GS ! Function: Code: Select character size ASCII Hex Decimal GS 1D 29 ! 21 33 n n n Range: 0 ≤ n ≤ 255 (1 ≤ Vertical enlargement ≤ 8, 1 ≤ Horizontal enlargement ≤ 8) Default: n=0 Description: ■ This command selects the character height and width using bits 0 to 3, and bits 4 to 7 respectively as follows: Bit Function Setting 0 1 2 3 4 5 6 7 Rev. 1.
SPP-R210 Command Manual • Table 1 [Enlarged in horizontal direction] Hex Decimal Enlargement 00 0 1 time (standard) 10 16 2 times 20 32 3 times 30 48 4 times 40 64 5 times 50 80 6 times 60 96 7 times 70 112 8 times • Table 2 [Enlarged in vertical direction] Hex Decimal Enlargement 00 0 1 time (standard) 01 1 2 times 02 2 3 times 03 3 4 times 04 4 5 times 05 5 6 times 06 6 7 times 07 7 8 times Remarks: ■ Differences: None Rev. 1.
SPP-R210 Command Manual Example: Input: 0x41 0x42 0x43 0x0a 0x1d 0x21 0x20 0x41 0x42 0x43 0x0a 0x1d 0x21 0x02 0x41 0x42 0x43 0x0a 0x1d 0x21 0x44 0x41 0x42 0x43 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual GS $ Function: Code: Set absolute vertical print position in page mode ASCII Hex Decimal GS 1D 29 $ 24 36 nL nL nL nH nH nH Range: 0 ≤ (nL + nH x 256) ≤ 65535 (0 ≤ nL ≤ 255, 0 ≤ nH ≤ 255) Default: None Description: This command sets the absolute vertical print starting position to [(nL + nH × 256) × (vertical or horizontal motion unit)]. Remarks: ■ ■ Differences: None Example: ■ Rev. 1.00 This command is activated only in page mode and ignored in standard mode.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual GS ( A Function: Code: Execute test print ASCII Hex Decimal GS 1D 29 ( 28 40 A 41 65 Range: (pL + pH x 256) = 2 (pL=2, pH=0) 0 ≤ n ≤ 2, 48 ≤ n ≤ 50 1 ≤ m ≤ 3, 49 ≤ m ≤ 51 Default: None Description: ■ Remarks: ■ ■ Differences: None Rev. 1.00 pL pL pL pH pH pH n n n m m m This command prints a specified pattern for testing on a roll paper.
SPP-R210 Command Manual GS ( F Function: Set black mark control functions Code: None Range: None Default: None Description: ■ This command performs various functions to control the black mark(BM) paper as follows: m Format Function Sets the paper feed amount to adjust the paper cutting position after 2 GS ( F pL pH m a nL nH sensing BM. 112 GS ( F pL pH m aL aH bL bH Specifies the black mark paper format. • pL, pH specifies (pL + (pH ×256)) as the number of bytes after pH (m and [parameter]).
SPP-R210 Command Manual GS ( F pL pH m a nL nH (m=2) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 F 46 70 pL 04 4 pH 00 0 m 02 2 Range: (pL + pH × 256) = 4 (pL = 4, pH = 0) m=2 a = 0, 48 0 ≤ (nL + nH × 256) ≤ 65535 (0 ≤ nL ≤ 255, 0 ≤ nH ≤ 255) Default: nL = 0, nH = 0 Description: ■ Remarks: ■ Differences: None Rev. 1.00 a a a nL nL nL nH nH nH This command sets the value for the adjustment of paper cutting position after sensing BM.
SPP-R210 Command Manual GS ( F pL pH m aL aH bL bH (m=112) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 F 46 70 pL 05 5 pH 00 0 m 70 112 aL aL aL aH aH aH bL bL bL bH bH bH Range: (pL + pH × 256) = 5 (pL = 5, pH = 0) m = 112 0 ≤ (aL + aH × 256) ≤ 65535 (0 ≤ aL ≤ 255, 0 ≤ aH ≤ 255) 0 ≤ (bL + bH × 256) ≤ 65535 (0 ≤ bL ≤ 255, 0 ≤ bH ≤ 255) Default: aL = 141, aH = 0 (BM height(top of a BM ~ bottom of BM): 20 mm) bL = 20, bH = 11 (BM interval(top of a BM ~ top of next BM): 400 mm) Des
SPP-R210 Command Manual GS ( k Function: Specify and print the symbol Code: None Range: None Default: None Description: ■ This command processes the data concerning two-dimensional code. • Symbol type is specified by cn. • Function code is specified by fn. cn Type of Symbol 48 PDF417 (2-dimensional code) 49 QR CODE (2-dimensional code) 50 MAXI CODE(2-dimensional code) 51 DATAMATRIX(2-dimensional code) 52 GS 1 DATABAR 53 AZTEC CODE cn 48 Rev. 1.
SPP-R210 Command Manual cn fn 65 67 69 80 Function 165 Function 167 Function 169 Function 180 Function QR CODE: Select the module QR CODE: Select the size of module QR CODE: Select the error correction level QR CODE: Store the data in the symbol storage area 50 81 65 80 Function 181 Function 265 Function 280 QR CODE: Print the data in the symbol storage area MAXI CODE: Select the mode MAXI CODE: Store the data in the symbol storage area 51 81 67 80 Function 281 Function 367 Function 380 MAXI CODE
SPP-R210 Command Manual GS ( k pL pH cn fn n (fn=65) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=48, fn=65 0 ≤ n ≤ 30 Default: n=0 Description: ■ Remarks: ■ ■ ■ Differences: None Rev. 1.00 pL 03 3 pH 00 0 cn 30 48 fn 41 65 n n n This command specifies the number of columns in the data area of PDF417. • When n=0, automatic processing is set • When n is not 0, the number of columns of the data area is set to n code word.
SPP-R210 Command Manual GS ( k pL pH cn fn n (fn=66) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=48, fn=66 n=0, 3 ≤ n ≤ 90 Default: n=0 Description: ■ Remarks: ■ ■ ■ Differences: None Rev. 1.00 pL 03 3 pH 00 0 cn 30 48 fn 42 66 n n n This command specifies the number of rows in the data area of PDF417. • When n=0, automatic processing is set • When n is not 0, the number of rows is set to n rows.
SPP-R210 Command Manual GS ( k pL pH cn fn n (fn=67) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 30 48 fn 43 67 n n n Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=48 fn=67 2≤n≤3 Default: n=3 Description: This command sets the width of the module of PDF417 symbol to n dots. Remarks: ■ ■ ■ Settings of this command affect the processing of Functions 081. The setting unit for printer models varies.
SPP-R210 Command Manual GS ( k pL pH cn fn n (fn=68) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 30 48 fn 44 68 n n n Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=48 fn=68 2≤n≤8 Default: n=3 Description: This command sets the module height of PDF417 to [the module width x n] Remarks: ■ ■ Differences: None Rev. 1.00 Settings of this command affect the processing of Functions 081.
SPP-R210 Command Manual GS ( k pL pH cn fn m n (fn=69) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 Range: (pL + pH x 256) = 4 (pL=4, pH=0) cn=48 fn=69 m=48 48 ≤ n ≤ 56 0≤n≤8 Default: None Description: ■ Remarks: ■ ■ Differences: None Rev. 1.00 pL 04 4 pH 00 0 Cn 30 48 fn 45 69 m m m n n n This command specifies the error correction level for PDF417. • The error correction level is set by “level” Settings of this function affect the processing of Functions 081.
SPP-R210 Command Manual GS ( k pL pH cn fn m (fn=70) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=48 fn=70 m=0,1 Default: m=0 Description: This command selects the option for PDF417. m Function 0 Select the standard PDF417 1 Select the simplified PDF417 Remarks: ■ ■ ■ Differences: None Rev. 1.00 cn 30 48 fn 46 70 m m m Settings of this function affect the processing of Functions 081.
SPP-R210 Command Manual GS ( k pL pH cn fn m d1...dk (fn=80) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL pL pL pH pH pH cn 30 48 fn 50 80 m 30 48 d1...dk d1...dk d1...dk Range: 4 ≤ (pL + pH x 256) ≤ 65535 (0 ≤ pL ≤ 255, 0 ≤ pH ≤ 255) cn=48 fn=80 m=48 0 ≤ d ≤ 255 k = (pL + pH x 256) – 3 Default: None Description: This command stores the PDF417 symbol data (d1...dk) in the symbol storage area. Remarks: ■ ■ Differences: None Rev. 1.
SPP-R210 Command Manual GS ( k pL pH cn fn m (fn=81) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 30 48 fn 51 81 m m m Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=48 fn=81 m=48 Default: None Description: This command encodes and prints the PDF417 symbol data in the symbol save area. Remarks: ■ Rev. 1.00 In standard mode, this command is available only when printer is at the beginning of a line or the printer buffer is empty.
SPP-R210 Command Manual ■ ■ ■ ■ ■ ■ ■ Differences: Rev. 1.00 The data area includes the following codewords: • Data specified by Function 080. • The descriptor of symbol length. (the first code word in the data area) • The error correction code word calculated by modulus 929. • Pad codeword.
SPP-R210 Command Manual Example: Input: 0x1d 0x28 0x6b 0x03 0x00 0x30 0x41 0x00 0x1d 0x28 0x6b 0x03 0x00 0x30 0x42 0x00 0x1d 0x28 0x6b 0x03 0x00 0x30 0x43 0x03 0x1d 0x28 0x6b 0x03 0x00 0x30 0x44 0x03 0x1d 0x28 0x6b 0x04 0x00 0x30 0x45 0x30 0x32 0x1d 0x28 0x6b 0x03 0x00 0x30 0x46 0x00 0x1d 0x28 0x6b 0x1b 0x00 0x30 0x50 0x30 0x5a 0x51 0x31 0x31 0x30 0x5f 0x5a 0x65 0x62 0x72 0x61 0x20 0x54 0x65 0x63 0x68 0x6e 0x6f 0x6c 0x6f 0x67 0x69 0x65 0x73 0x1d 0x28 0x6b 0x03 0x00 0x30 0x51 0x30 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual GS ( k pL pH cn fn n1 n2 (fn=65) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 04 4 pH 00 0 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=49 fn=65 n1 = 49, 50 n2 =0 Default: n1=50, n2 =0 Description: This command sets the QR Code model as follows: n1 Function 49 Model 1 50 Model 2 Remarks: ■ ■ Differences: None Rev. 1.00 cn 31 49 fn 41 65 n1 n1 n1 n2 n2 n2 The setting of this command affects .
SPP-R210 Command Manual GS ( k pL pH cn n (fn=67) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 31 49 fn 43 67 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=49 fn=67 0<=n<9 Default: n=3 Description: This command sets the size of the QR Code module to n dots. Remarks: ■ ■ ■ Differences: None Rev. 1.00 n n n The setting of this command affects the processing of .
SPP-R210 Command Manual GS ( k pL pH cn n (fn=69) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 31 49 fn 45 69 n n n Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=49 fn=69 48≤n≤51 Default: n=48 Description: This command sets the error correction level for QR Code. n Function Recovery Amount (%) 48 Error Correction Level L 7 49 Error Correction Level M 15 50 Error Correction Level Q 25 51 Error Correction Level H 30 Remarks: ■ ■ ■ Differences: None Rev.
SPP-R210 Command Manual GS ( k pL pH cn fn m d1...dk (fn=80) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL pL pL pH pH pH cn 31 49 fn 50 80 m 30 48 Range: 4 ≤ (pL + pH x 256) ≤7092 (0 ≤ pL ≤ 255, 0 ≤ pH ≤ 27) cn=49 fn=80 m=48 0 ≤ d ≤ 255 k = (pL + pH x 256) – 3 Default: None Description: This command saves symbol data of the QR Code to the symbol storage area. Remarks: ■ Differences: None Rev. 1.00 d1...dk d1...dk d1...
SPP-R210 Command Manual GS ( k pL pH cn fn m (fn=81) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 31 49 fn 51 81 m m m Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=49 fn=81 m=48 Default: None Description: This command encodes and prints QR Code symbol data saved in the symbol storage area. Remarks: ■ Rev. 1.00 In standard mode, this command is available only when printer is at the beginning of a line or the printer buffer is empty.
SPP-R210 Command Manual The following data is automatically added by the encoding processing: • Position sensor pattern • Segregator for the position sensor pattern • Timing pattern • Format information • Version information • Error correction code text • Pad code text • Indicator for counting bits of bytes • Mode indicator • Concluder • Queue pattern (when model 2 is selected) • Expansion pattern (when model 1 is selected) ■ Except for character size and upside-down printing mode, none of print mode such a
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual GS ( k pL pH cn fn n1 n2 (fn=65) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=50 fn=65 50 ≤ n ≤ 52 Default: n = 50 Description: This command selects the mode for Maxi Code n Function 50 Mode 2 Setting 51 Mode 3 Setting 52 Mode 4 Setting Remarks: ■ ■ Differences: None Rev. 1.00 cn 32 50 fn 41 65 n n n The setting of this command affects .
SPP-R210 Command Manual GS ( k pL pH cn fn m d1...dk (fn=80) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL pL pL pH pH pH cn 32 50 fn 50 80 m 30 48 Range: 4 ≤ (pL + pH x 256) ≤ 141 (4 ≤ pL ≤141, 0 ≤ pH ≤0) cn=50 fn=80 m=48 0 ≤ d ≤ 255 k = (pL + pH x 256) – 3 Default: None Description: This command stores Maxi Code symbol data in the symbol storage area. Remarks: ■ Differences: None Rev. 1.00 d1...dk d1...dk d1...
SPP-R210 Command Manual GS ( k pL pH cn fn m (fn=81) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 32 50 fn 51 81 m m m Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=50 fn=81 m=48 Default: None Description: This command encodes and prints Maxi Code symbol data saved in the storage area. Remarks: ■ Rev. 1.00 In standard mode, this command is available only when printer is at the beginning of a line or the printer buffer is empty.
SPP-R210 Command Manual Modes 2 and 3 are executed according to the following procedures: (RS, GS indicates the control code of MAXI CODE. y indicates the 2-byte numeric data.) a) 9-byte data including ” [)>”,”RS”,”01”,”GS”,”yy” are regarded as the Header. • The next data following the Header is the Primary Message. • When printing, the Header is placed at the beginning of the Secondary Message. b) When Header data is absent, the data is regarded as Primary Message.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual GS ( k pL pH cn n (fn=67) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=51 fn=67 2≤n≤3 Default: n=3 Description: This command sets the DATAMATRIX Code size. Remarks: ■ ■ ■ Differences: None Rev. 1.00 cn 33 51 fn 43 67 n n n This command affects the execution of . The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
SPP-R210 Command Manual GS ( k pL pH cn fn m d1...dk (fn=80) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL pL pL pH pH pH cn 33 51 fn 50 80 m 30 48 Range: 0 ≤ (pL + pH x 256) ≤ 3116 (0≤ pL ≤255, 0 ≤ pH ≤13) cn=51 fn=80 m=48 0 ≤ d ≤ 255 k = (pL + pH x 256) – 3 Default: None Description: This command stores DATAMATRIX symbol data in the symbol storage area. Remarks: ■ Differences: None Rev. 1.00 d1...dk d1...dk d1...
SPP-R210 Command Manual GS ( k pL pH cn fn m (fn=81) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 33 51 fn 51 81 m m m Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=51 fn=81 m=48 Default: None Description: This command encodes and prints DATAMATRIX symbol data saved in the storage area. Remarks: ■ ■ ■ ■ ■ ■ Rev. 1.00 In standard mode, this command is available only when printer is at the beginning of a line or the printer buffer is empty.
SPP-R210 Command Manual In standard mode, the paper feed amount set by the paper feed setting command does not affect printing of the symbol. The printing position returns to the left side of the printable area after printing the symbol. ■ In page mode, the printer stores the symbol data in the print buffer without executing actual printing. ■ The quiet zone is not included in the printing data. Be sure to include the adequate quiet zone for executing of this command.
SPP-R210 Command Manual GS ( k pL pH cn fn n (fn=65) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 34 52 fn 41 65 n n n Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=52 fn=65 50 ≤ n ≤ 60 Default: n=50.
SPP-R210 Command Manual GS ( k pL pH cn fn n (fn=66) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 34 52 fn 42 66 n1 n1 n1 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=52 fn=66 1 ≤ n1 ≤ 8, 1 ≤ n2 ≤ 8 Default: n1=2 n2=2 Description: Set the size of .the GS1 DataBar module height to n1, width to n2 dots. Remarks: ■ ■ Differences: None Rev. 1.
SPP-R210 Command Manual GS ( k pL pH cn fn n (fn=68) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 34 52 fn 44 68 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=52 fn=68 1 ≤ n ≤ 255 Default: n = 32 Description: Set the module segment height of UCC/EAN-128 barcode type. This settings will be effective only UCC/EAN-128 barcode type. Remarks: ■ ■ Differences: None Rev. 1.
SPP-R210 Command Manual GS ( k pL pH cn fn n (fn=70) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 34 52 fn 46 70 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=52 fn=70 1≤n≤2 Default: n=2 Description: Specify the height of separator between 2D and 1D barcode symbol. Remarks: ■ ■ Differences: None Rev. 1.
SPP-R210 Command Manual GS ( k pL pH cn fn m d1...dk (fn=80) Code: Range: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL pL pL pH pH pH cn 34 52 m 30 48 0 ≤ (pL + pH x 256) ≤ 215 (0≤ pL ≤215, pH = 0) cn=52 fn=80 m=48 0 ≤ d ≤ 255 k = (pL + pH x 256) – 3 Data format : number1...numberN|character1...
SPP-R210 Command Manual GS1 DataBar holds a 14-digit number. GS1 DataBar can carry GTIN-12, GTIN-13 & GTIN-14 Numeric character(0-9) – No alpha numeric, no special characters. Fiex data length – 14digits(encodes 13 with an implied check digit) AI(01) is implied. Limeted to GTIN-12, 13 and GTIN-14 with indicator digit 1 only(no other number can be used as an indicator digit) ■ The setting of this command remains effective until ESC @, printer reset or power cycling is executed. ■ ■ ■ Differences: Rev. 1.
SPP-R210 Command Manual GS ( k pL pH cn fn m (fn=81) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 34 52 fn 51 81 m m m Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=52 fn=81 m=48 Default: None Description: This command encodes and prints GS1 DataBar symbol data saved in the storage area. Remarks: ■ Differences: None Example: ■ Rev. 1.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual GS ( k pL pH cn fn n (fn=65) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=53 fn=65 1≤n≤8 Default: n=2 Description: Set the size of .the Aztec barcode module to n dots. Remarks: ■ ■ Differences: None Rev. 1.
SPP-R210 Command Manual GS ( k pL pH cn fn n (fn=66) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 34 52 fn 46 70 n n n Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=53 fn=66 48 ≤ n ≤ 51 Default: n=49 Description: Sets the error correction level of the AZTEC code n Function Recovery Amount (%) 48 Error Correction Level L 10 49 Error Correction Level M 23 50 Error Correction Level Q 36 51 Error Correction Level H 50 ■ The setting of this function impacts the
SPP-R210 Command Manual GS ( k pL pH cn fn n (fn=67) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=53 fn=67 0≤n≤2 Default: n=0 Description: Set the mode of .the Aztec barcode module. Remarks: ■ ■ ■ ■ ■ ■ Differences: None Rev. 1.00 pH 00 0 cn 35 53 fn 43 67 n n n n=0 : data mode, n=1 : gs1 mode, n=2 : unicode mode. In gs1 mode, Extended ASCII characters and control characters are not suppored.
SPP-R210 Command Manual GS ( k pL pH cn fn m d1…dk Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL pL pL pH pH pH cn 35 53 Range: 0 ≤ (pL + pH x 256) ≤ 3803 (0 ≤ pL ≤ 255, 0 ≤ pH ≤ 14) cn=53 fn=80 m=48 0 ≤ d ≤ 255 k = (pL + pH x 256) - 3 Default: None Description: Store Aztec barcode symbol data in the symbol storage area. Remarks: ■ Differences: None Rev. 1.00 fn 50 80 m 30 48 (fn=80) d1...dk d1...dk d1...
SPP-R210 Command Manual GS ( k pL pH cn fn m (fn=81) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 k 6B 107 pL 03 3 pH 00 0 cn 35 53 fn 51 81 m m m Range: (pL + pH x 256) = 3 (pL=3, pH=0) cn=53 fn=81 m=48 Default: None Description: This command encodes and prints Aztec barcode symbol data saved in the storage area. Remarks: ■ Differences: None Example: ■ Rev. 1.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual GS ( L, GS 8 L Function: Code: Select graphics data ASCII Hex Decimal GS 1D 29 ( 28 40 L 4C 76 pL pL pL pH pH pH m m m fn fn fn ASCII Hex Decimal GS 1D 29 8 38 56 L 4C 76 p1 p1 p1 p2 p2 p2 p3 p3 p3 p4 p4 p4 [parameter] [parameter] [parameter] m m m fn fn fn [parameter] [parameter] [parameter] Range: None Default: None Description: This command processes graphics data according to the function code (fn). fn Format Function No.
SPP-R210 Command Manual Remarks: ■ ■ ■ Differences: None Rev. 1.00 This command is adapted to print image data. pL, pH specifies the number of bytes following pH using (pL + pH x 256). Since frequent writing operation could cause the damage to the NV memory, it is recommended to write only when being required. ■ While storing data by this command, the printer is in BUSY state where receiving of data is not available. Therefore, it is not recommended to send data during this process.
SPP-R210 Command Manual GS ( L pL pH m fn (fn=0, 48) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 L 4C 76 Range: (pL + pH x 256) = 2 (pL=2, pH=0) m=48, fn=0, 48 Default: None Description: ■ Remarks: None Differences: ■ Rev. 1.00 pL pL pL pH pH pH m m m fn fn fn Transmits the total capacity of the NV bit-image memory (number of bytes in the memory area).
SPP-R210 Command Manual BS ^ L pL pH fn (fn=2, 50) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 L 4C 76 pL pL pL pH pH pH m m m fn fn fn Range: (pL + pH x 256) = 2 (pL=2, pH=0) m=48, fn=2, 50 Default: None Description: This command prints the graphics data defined by the process of Function 112. Remarks: ■ ■ ■ ■ The graphics data stored in the printer buffer is printed. This command is available in standard mode, not in page mode. The graphics data is defined by Function 112.
SPP-R210 Command Manual GS ( L pL pH m fn (fn=3, 51) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 L 4C 76 Range: (pL + pH x 256) = 2 (pL=2, pH=0) m=48, fn=3, 51 Default: None Description: ■ Remarks: None Differences: None Rev. 1.00 pL pL pL pH pH pH m m m fn fn fn Transmits the number of bytes of remaining memory (unused area) in the NV user memory.
SPP-R210 Command Manual GS ( L pL pH m fn d1 d2 Code: ASCII Hex Decimal GS 1D 29 ( 28 40 L 4C 76 Range: (pL + pH x 256) = 4 (pL=4, pH=0) m=48 fn=64 d1=75, d2=67 Default: None Description: ■ pL pL pL pH pH pH m m m Transmits the defined NV graphics key code list.
SPP-R210 Command Manual ■ After the [Header-NULL] is transmitted, the printer receives a response from the host; then it performs the process defined by the response. (See the tables below.) - When the status (existence of the next data block) is Hexadecimal = 41H / Decimal = 65 Response Process performed ASCII Decimal ACK 6 Transmits the next data. NAK 21 Transmits the previous data again. CAN 24 Ends the process.
SPP-R210 Command Manual GS ( L pL pH m fn d1 d2 d3 (fn=65) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 L 4C 76 pL pL pL pH pH pH Range: (pL + pH x 256) = 5 (pL=5, pH=0) m=48 fn=65 d1=67, d2=76, d3=82 Default: None Description: This command removes all defined NV graphics data. Remarks: ■ Differences: None Rev. 1.
SPP-R210 Command Manual GS ( L pL pH m fn kc1 kc2 (fn=66) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 L 4C 76 pL pL pL pH pH pH m m m fn fn fn kc1 kc1 kc1 Range: (pL + pH x 256) = 4 (pL=4, pH=0) m=48 fn=66 32 ≤ kc1 ≤ 126 32 ≤ kc2 ≤ 126 Default: None Description: This command deletes the NV graphics data corresponding to kc1 and kc2. Remarks: ■ ■ Differences: None Rev. 1.00 kc2 kc2 kc2 The graphics data is define by Function 67.
SPP-R210 Command Manual GS ( L pL pH m fn a kc1 kc2 b xL xH yL yH [c d1...dk]1...[c d1...dk]b (fn=67) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 L 4C 76 pL pH m fn a kc1 kc2 b xL xH yL yH [c d1...dk]1...[c d1...dk]b pL pH m fn a kc1 kc2 b xL xH yL yH [c d1...dk]1...[c d1...dk]b pL pH m fn a kc1 kc2 b xL xH yL yH [c d1...dk]1...[c d1...
SPP-R210 Command Manual GS ( L pL pH m fn kc1 kc2 b x y (fn=69) Code: ASCII Hex Decimal GS 1D 29 ( 28 40 L 4C 76 pL pL pL pH pH pH m m m fn fn fn Range: (pL + pH x 256) = 6 (pL=6, pH=0) m=48, fn=69 32 ≤ kc1 ≤ 126 32 ≤ kc2 ≤ 126 x=1, 2 y=1, 2 Default: None Description: ■ Remarks: ■ ■ ■ This command prints the NV graphics data defined by Function 67. In page mode, this command is not effective. NV graphics data beyond the print area for one line is not printed.
SPP-R210 Command Manual GS ( L pL pH m fn a bx by c xL xH yL yH d1...dk Code: ASCII Hex Decimal GS 1D 29 ( 28 40 L 4C 76 (fn=112) pL pH m fn a bx by c xL xH yL yH d1...dk pL pH m fn a bx by c xL xH yL yH d1...dk pL pH m fn a bx by c xL xH yL yH d1...
SPP-R210 Command Manual GS : Function: Code: Start/end macro definition ASCII Hex Decimal GS 1D 29 : 3A 58 Range: None Default: None Description: ■ This command starts or ends macro definition. Remarks: ■ The printer starts macro definition during normal operation and finishes it during macro definition upon receiving this command. The printer performs printing during macro definition. The macro is executed by GS ^.
SPP-R210 Command Manual GS B Function: Turns white/black reverse printing mode on / off Code: ASCII Hex Decimal Range: 0 ≤ n ≤ 255 Default: n=0 Description: ■ This command selects white/black reverse printing mode by setting the least significant bit of n. • When the LSB of n is 0, white/black reverse mode is turned off. • When the LSB of n is 1, white/black reverse mode is turned on. Remarks: ■ ■ ■ ■ This command does not affect multi-byte characters such as Kanji, Japanese and Korean.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual GS H Function: Code: Selects print position of HRI characters ASCII Hex Decimal GS 1D 29 H 48 72 n n n Range: 0 ≤ n ≤ 3, 48 ≤ n ≤ 51 Default: n=0 Description: ■ This command selects the printing position of HRI (Human Readable Interpretation) characters when printing a bar code.
SPP-R210 Command Manual Example: Input: 0x1d 0x68 0x50 0x1d 0x48 0x00 0x1d 0x6b 0x49 0x0a 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x1b 0x64 0x03 0x1d 0x48 0x01 0x1d 0x6b 0x49 0x0a 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x1b 0x64 0x03 0x1d 0x48 0x02 0x1d 0x6b 0x49 0x0a 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x1b 0x64 0x03 0x1d 0x48 0x03 0x1d 0x6b 0x49 0x0a 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual GS I Function: Transmits printer ID Code: ASCII Hex Decimal Range: 1 ≤ n ≤ 69 Default: None Description: ■ Remarks: ■ Rev. 1.00 GS 1D 29 I 49 73 n n n This command transmits the printer ID or information.
SPP-R210 Command Manual Differences: ■ The printer ID is shown according to printer models as follows: Printer ID SPP-R210 1(Printer model ID) 0x41 Type ID varies depending on functions the printer supports as follows: - 0x01 (Multi-byte character) - 0x02 (Autocutter) 2(Type ID) - 0x03 (Autocutter + Multi-byte character) - 0x04 (Customer display) - 0x05 (Multi-byte character + Display) - 0x07 (Customer display + Autocutter + Multi-byte Character) 3(Printer feature ID) 0x69 66(Manufacturer) BIXOLO
SPP-R210 Command Manual GS I b Function: Code: Transmits battery status ASCII Hex Decimal Range: None Default: None Description: ■ Remarks: ■ ■ ■ Differences: None Rev. 1.00 GS 1D 29 I 49 73 b 62 98 This command transmits the battery power status of the printer.
SPP-R210 Command Manual GS L Function: Code: Set left margin ASCII Hex Decimal GS 1D 29 L 4C 76 nL nL nL nH nH nH Range: 0 ≤ nL ≤ 255, 0 ≤ nH ≤ 255 Default: (nL + nH x 256)=0 (nL=0, nH=0) Description: This command sets the left margin specified to [(nL + nH x 256) x (horizontal motion units)]. Remarks: ■ The left margin is not effective in page mode. If the left margin is enabled in page mode, the setting is available when the printer returns to standard mode.
SPP-R210 Command Manual Example: Input: 0x41 0x42 0x43 0x44 0x45 0x0a 0x41 0x42 0x43 0x44 0x45 0x0a 0x1d 0x4c 0x30 0x00 0x41 0x42 0x43 0x44 0x45 0x0a 0x41 0x42 0x43 0x44 0x45 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual GS T Function: Code: Set print position to the beginning of print line ASCII Hex Decimal GS 1D 29 Range: n=0, 1, 48, 49 Default: None Description: ■ Remarks: ■ ■ Differences: None Example: ■ Rev. 1.00 T 54 84 n n n This command sets the print position to the beginning of the print line. • n specifies how data in the print buffer is processed when this command is executed. n Function 0, 48 Sets the print position after the data in the print buffer is deleted.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual GS W Function: Code: Set printing area width ASCII Hex Decimal GS 1D 29 W 57 87 nL nL nL nH nH nH Range: 0 ≤ nL ≤ 255, 0 ≤ nH ≤ 255 Default: (nL + nH x 256)=384 (nL=80, nH=1) Description: This command sets the printing area width to [(nL + nH x 256) x (horizontal motion units)]. Remarks: ■ The printing area width is not effective in page mode. If the printing area width is enabled in page mode, the setting is available when the printer returns to standard mode.
SPP-R210 Command Manual Example: Input: 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x31 0x32 0x0a 0x1d 0x57 0xc0 0x00 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x31 0x32 0x0a 0x1d 0x57 0x60 0x00 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0
SPP-R210 Command Manual GS \ Function: Code: Set relative vertical print position in page mode ASCII Hex Decimal GS 1D 29 \ 5C 92 nL nL nL nH nH nH Range: 0 ≤ nL ≤ 255, 0 ≤ nH ≤ 255 Default: None Description: This command moves the vertical print position to [(nL + nH x 256) x (vertical or horizontal motion units)] relative to the current position in page mode. Remarks: ■ ■ ■ ■ Differences: None Example: ■ Rev. 1.00 This command is effective in page mode.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual GS ^ Function: Execute macro Code: ASCII Hex Decimal Range: 0 ≤ r ≤ 255 0 ≤ t ≤ 255 m=0, 1 Default: None Description: ■ This command executes a macro using parameters as following: • r specifies the number of times to execute the macro. • t specifies the waiting time before the macro is executed. • m specifies macro executing mode as shown below. m Function 0 Executes the macro r times continuously at the interval specified by t.
SPP-R210 Command Manual GS a Function: Enable/Disable Automatic Status Back (ASB) Code: ASCII Hex Decimal Range: 0 ≤ n ≤ 255 Default: n=0 GS 1D 29 a 61 97 n n n Printers: Description: ■ This enables or disables ASB (Automatic Status Back) according to n. • ASB is enabled when n > 0. Remarks: ■ ASB is the function that transmit the printer status such as cover open/close and Online/Offline] continuously at the time interval specified regardless of the status change if ASB is enabled.
SPP-R210 Command Manual ■ The printer information transmitted is comprised of 4 bytes as follows: • First byte(printer information) Bit Off/On Hex Decimal Function 0 Off 00 0 Not used. Fixed to Off 1 Off 00 0 Not used. Fixed to Off 2 On 04 4 Not used. Fixed to On Off 00 0 On-line 3 On 08 8 Off-line 4 Off 10 16 Not used.
SPP-R210 Command Manual Third byte (paper sensor information) Bit Off/On Hex Decimal 0,1 Off 00 0 Off 00 0 2,3 On 0C 12 4 Off 00 0 5 Off 00 0 6 Off 00 0 7 Off 00 0 Not used. Fixed to Off Paper end sensor: paper present Paper end sensor: no paper present Not used. Fixed to Off Not used. Fixed to Off Not used. Fixed to Off Not used. Fixed to Off Fourth byte (paper sensor information) Bit Off/On Hex Decimal 0 On 01 1 1 On 02 2 2 On 04 4 3 On 08 8 4 Off 00 0 5 Off 00 0 6 Off 00 0 7 Off 00 0 Not used.
SPP-R210 Command Manual GS f Function: Code: Select font for HRI characters ASCII Hex Decimal GS 1D 29 f 66 102 n n n Range: n=0, 1, 48, 49 Default: n=0 Description: This command selects a font for the HRI(Human Readable Interpretation) characters used when printing a bar code, using n as follows: n Font 0, 48 Font A 1, 49 Font B Remarks: ■ ■ ■ The setting of this command is applied to only HRI characters. The printing position of HRI characters are specified by GS H.
SPP-R210 Command Manual Example: Input: 0x1d 0x68 0x50 0x1d 0x48 0x02 0x1d 0x66 0x01 0x1d 0x6b 0x49 0x0a 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x0a 0x1d 0x66 0x00 0x1d 0x6b 0x49 0x0a 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual GS h Function: Selects bar code height Code: ASCII Hex Decimal Range: 1 ≤ n ≤ 255 Default: n=162 Description: This command sets the height of the bar code to n dots. Remarks: ■ ■ The unit of n depends on the printer model. The setting of this command remains effective until ESC @, printer reset or power cycling is executed. Differences: ■ Unit of one dot: 0.125mm(1/203 inch) Example: ■ Rev. 1.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual GS k Function: Print bar code Code: ① ② ASCII Hex Decimal ASCII Hex Decimal GS 1D 29 GS 1D 29 k 6B 107 k 6B 107 m m m m m m Range: ①0≤m≤6 ② 65 ≤ m ≤ 73 K, m, n depend on the barcode system Default: None Description: ■ Rev. 1.00 d1...dk d1...dk d1...dk n n n NUL NUL NUL d1...dn d1...dn d1...dn This command selects a bar code system and prints the bar code. • k indicates the number of bytes of bar code data. • n specifies the number of bytes of bar code data.
SPP-R210 Command Manual For range ② m 65 66 67 68 Bar Code System UPC-A UPC-E JAN13(EAN) JAN8(EAN) Range of k 11 ≤ n ≤ 12 11 ≤ n ≤ 12 12 ≤ n ≤ 13 7≤n≤8 69 CODE39 1 ≤ n ≤ 255 70 ITF 1 ≤ n ≤ 255 (even number) 71 CODABAR 1 ≤ n ≤ 255 72 73 CODE93 CODE128 1 ≤ n ≤ 255 2 ≤ n ≤ 255 Remarks: ■ ■ Differences: None Example: ■ Rev. 1.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual GS r Function: Code: Transmit status ASCII Hex Decimal GS 1D 29 r 72 114 n n n Range: n=1, 2, 49, 50 Default: None Description: The command transmits the status specified by n as follows: n Function 1, 49 Transmits paper sensor status Remarks: ■ ■ Differences: None Rev. 1.00 The status is one byte.
SPP-R210 Command Manual GS v 0 Function: Code: Print raster bit image ASCII Hex Decimal GS 1D 29 v 76 118 0 30 48 m m m xL xH xL xH xL xH Range: 0 ≤ m ≤ 3, 48 ≤ m ≤ 51 1 ≤ (xL + xH x 256) ≤ 384 (0 ≤ xL ≤ 80, 0 ≤ xH ≤ 1) 1 ≤ (yL + yH x 256) ≤ 1662 (0 ≤ yL ≤ 126, 0 ≤ yH ≤ 6) 0 ≤ d ≤ 255 1≤ k ≤ 119664 Default: None Description: ■ yL yH d1...dk yL yH d1...dk yL yH d1...dk This command prints a raster bit image according to the mode defined by m. DPI : Dots per Inch (25.
SPP-R210 Command Manual Differences: m 0, 48 1, 49 2, 50 3, 51 Rev. 1.00 Mode Normal Double-width Double-height Quadruple Vertical dot density (DPI) 203 203 203/2 203/2 BIXOLON DPI : Dots per Inch (25.
SPP-R210 Command Manual GS w Function: Code: Set bar code width ASCII Hex Decimal Range: 2≤n≤6 Default: n=3 Description: ■ Remarks: ■ Differences: None Rev. 1.00 GS 1D 29 w 77 119 n n n This command sets the horizontal size of the bar code, using n as follows: Binary-level bar code Multi-level bar code module n width (mm) Thin element width (mm) Thick element width (mm) 2 0.250 0.250 0.625 3 0.375 0.375 1.000 4 0.500 0.500 1.250 5 0.625 0.625 1.625 6 0.750 0.750 2.
SPP-R210 Command Manual Example: Input: 0x1d 0x68 0x50 0x1d 0x77 0x02 0x1d 0x6b 0x46 0x0a 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x0a 0x1d 0x77 0x04 0x1d 0x6b 0x46 0x0a 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 0x30 0x0a ■ ■ Rev. 1.
SPP-R210 Command Manual BS L A Function: Code: Execute automatic calibration in black mark mode ASCII Hex Decimal BS 08 8 L 4C 76 A 41 65 Range: None Default: None Description: This command executes auto calibration in black mark mode. Remarks: ■ ■ Differences: None Rev. 1.00 This command is effective only in the black mark mode. This command feeds 3 black marks to read the black mark and stores the optimal value into NV memory that is used to locate the black mark.
SPP-R210 Command Manual BS L L Function: Code: Select black mark mode ASCII Hex Decimal Range: None Default: None Description: ■ Remarks: ■ ■ Differences: None Rev. 1.00 BS 08 8 L 4C 76 L 4C 76 This commands selects black mark mode • The label mode must be set for printing on the black mark paper. This command is enabled in receipt mode. This command can activate the black mark mode even if the receipt mode is predefined by the memory switch(Msw8-5).
SPP-R210 Command Manual BS L R Function: Code: Select receipt mode ASCII Hex Decimal Range: None Default: None Description: ■ Remarks: ■ ■ Differences: None Rev. 1.00 BS 08 8 L 4C 76 R 52 82 This command selects receipt mode • The receipt mode must be set for printing on the continuous roll paper. This command is enabled only in label mode. This command can activate the receipt mode even if the label mode is predefined by the memory switch(Msw8-5).
SPP-R210 Command Manual BS M Function Code: Select device font type ASCII Hex Decimal BS 08 08 M 4D 77 n n n m m m Range: 65 ≤ m ≤ 67 ( m = 65,66,67) n=0 Default: n=0 Description: ■ Font type select by m value as follows: m Function ( Select font type ) 65 Font A (12x24) 66 Font B (9x17) 67 Font C (9x24) Remarks: ■ The setting of this command remains effective until ESC !, ESC M ESC @, printer reset or power cycling is executed. Example: ■ Rev. 1.
SPP-R210 Command Manual ■ Rev. 1.
SPP-R210 Command Manual BS M S Function Code: Sentinel character set up commands ASCII Hex Decimal BS 08 08 M 4D 77 S 53 83 pL pL pL pH pH pH Range: 0≤n≤2 (pL+pHx256) = 2 fn=49 Default: Depends on memory switch 8-6~7 setting value. Description: ■ fn1 fn1 fn1 Sets sentinel characters by n value as follows: n Mode 0, 48 Normal 1, 49 1-byte sentinel character 2, 50 Multi-byte sentinel characters n n n Description Transmits data as normal data without sentinel characters.
SPP-R210 Command Manual - When set to Multi-byte sentinel characters mode, characters after End characters are automatically applied to the card data to be transmitted to host. Remarks: MSR Data Transmission Format by Setting Mode Refer to ESC M command and the function 3 memory switch #7 (8 – 6 & 7 setting) of GS ( E command.
SPP-R210 Command Manual - When set to Track 3 Read mode Normal mode 02H 44H 31H 31H 1CH Max DATA104 characters (3Track data) 03H 0DH 0AH 1byte sentinel character mode 02H 44H 31H 31H 1CH (Header) 3BH (STX) Max DATA 104 characters (3Track data) 3FH 03H 0DH 0AH (End) (ETX) Multi byte sentinel characters mode START characters END characters Max DATA 104 characters (3Track data) 0DH 0AH (Max 10 byte) (Max 10 byte) - When set to Track 1/2 Read mode Normal mode 02H 43H 31H 31H 1CH Max DATA 76 characters (1Track
SPP-R210 Command Manual - When set to Track 2/3 Read mode Normal mode 02H 45H 31H 31H 1CH 1CH Max DATA 37 characters (2Track data) 1CH Max DATA104 Characters 03H 0DH 0AH (3Track data) 1byte sentinel character mode 02H 45H 31H 31H 1CH Max DATA37 Max DATA104 3BH 3FH 1CH 3BH 1CH characters Characters (STX) (ETX) (Separator) (STX) (Header) (2Track data) (3Track data) Multi byte sentinel characters mode START characters Max DATA 37 characters END characters (Max 10 byte) 0DH 0AH (Max 10 byte) (2Track data) 3F
SPP-R210 Command Manual Multi byte sentinel character mode START characters Max DATA 76 characters END characters (Max 10 byte) 0DH 0AH (Max 10 byte) (1Track data) START characters Max DATA 37 characters END characters (Max 10 byte) 0DH 0AH (Max 10 byte) (2Track data) START characters Max DATA 104 characters END characters (Max 10 byte) 0DH 0AH (Max 10 byte) (3Track data) Differences: Rev. 1.
SPP-R210 Command Manual BS M S PL PH fn2 m d1~dk Function Code: Set start sentinel characters ASCII Hex Decimal BS 08 08 M 4D 77 S 53 83 Range: 3 ≤ (pL+pHx256) ≤ 12 m = 49, 50, 51 32 ≤d ≤127, k ≤ 10 fn = 50 Default: Track 1 : “START1 “ Track 2 : “START2 “ Track 3 : “START3 “ Description: ■ ■ Remarks: None Rev. 1.00 pL pL pL pH pH pH fn2 32 50 m m m d1~dk d1~dk d1~dk m defines the track to set Start characters. d indicates the characters to be set as Start characters.
SPP-R210 Command Manual BS M S Function Code: Set end sentinel characters ASCII Hex Decimal BS 08 08 M 4D 77 S 53 83 Range: 3 ≤ (pL+pHx256) ≤ 12 m = 49, 50, 51 32 ≤d ≤127, k ≤ 10 fn = 50 Default: Track 1 : “END” Track 2 : “END” Track 3 : “END” Description: ■ ■ Remarks: None Rev. 1.00 PL PH fn3 m d1~dk pL pL pL pH pH pH fn3 33 51 m m m d1~dk d1~dk d1~dk m defines the track to set an End character. d indicates the character to be set as an End character.
SPP-R210 Command Manual BS M S PL PH fn4 m Function Code: Transmit Start and End characters setting information ASCII Hex Decimal BS 08 08 Range: (pL+pHx256) = 2 fn = 50 m = 49, 50, 51 Default: None Description: ■ ■ Remarks: None Rev. 1.00 M 4D 77 S 53 83 pL pL pL pH pH pH fn4 34 52 m m m m defines the track to be transmitted.