3Mbps Packet Length: 3-DH1
TRM/CA/01/C Output power(class1)
0
8
12
dBm
TRM/CA/01/C Output power(class2)
-6
0
4
dBm
GPS
Test Items
Test condition
Min
Typical
Max
Unit
CN ration
Satellites@-130dBm
-
38
40
dBm
Sensitivity
-
-145
-
dBm
3.5.13. Electrostatic Discharge
The module is not protected against Electrostatic Discharge (ESD) in general.
Consequently, it is subject to ESD handling precautions that typically apply to ESD
sensitive components. Proper ESD handling and packaging procedures must be applied
throughout the processing, handling and operation of any application that incorporates a
FREY M1 module.
Electrostatic discharge (ESD) may lead to irreversible damage for the module. It is
therefore advisable to develop measures and methods to counter ESD and to use these to
control the electrostatic environment at manufacturing sites.
Specification
ANSI/ESDA/JEDEC JS-001-2011
± 1KV Human Body Model (HBM)
JESD22-A114-F
± 500V Charge Device Model (CDM)
EN301-489
± 4KV (Indirect discharge) *
± 8KV (Air discharge) **
Note * : Indirect discharge with coupling metal plane .