User's Manual
Page 28
BitaTek Co., Ltd. Copyright protected. All rights reserved.
NO. 115 Wugong 3rd Rd., Tel +886 2 2298 8588
Wugu Dist., New Taipei City 248, Taiwan (R.O.C.) Fax+886 2 2290 0029
3.5. Electrical Specification
3.5.1. Input power specification
Absolute maximum rating:
Operating FREY M1 under conditions beyond its absolute maximum ratings may damage
the device. Absolute maximum ratings are limiting values to be considered individually
when all other parameters are within their specified operating ranges. Functional operation
and specification compliance under any absolute maximum condition, or after exposure to
any of these conditions, is not guaranteed or implied. Exposure may affect device reliability.
Parameter
Min.
Max.
Units
USB_VBUS_IN
0
25
V
VPH_PWR
0
6
V
CHG_OUT (VBAT)
Steady state
0
5
V
CHG_OUT (VBAT)
Transient (< 10 ms)
0
6
V
Operation condition:
Operating conditions include parameters that are under the control of the user : power supply
voltage and ambient temperature. The FREY M1 meets all performance specifications listed in
this document when used and/or stored within the operating conditions, unless otherwise noted
in those sections (provided the absolute maximum ratings have never been exceeded).
Parameter
Min.
Max.
Units
USB_VBUS_IN
4.0
10
V
VPH_PWR
3.5
4.5
V
CHG_OUT (VBAT)
3.5
4.5
V
Note : There is battery detection algorithm in FREY M1 , user need to implement battery ID and
thermal pin on the system , otherwise system can't be powered on successfully .