User's Manual

Please must stop using immediately if you find there are some situations
as below which might be caused by device failure or unknown failure:
Power is full but it will turn off very soon after using.
When Charging with AC adapter or USB cable, the device becomes very hot.
before the 1
st
time use under the temperature of 5℃~35.
1Charging with AC adapter:
You can start power charging through This AC port and mind the direction of Plug-in.
2Charging with USB cable:
You can also start power charging through AC cable connected with the PC USB
port .
The Ac cable one site is USB that can not transfer data from Cyclops II to PC only
for power charge.
It will take about 2.5hrs to charge full power with AC adapter.
It will take about 3hrs to charge full power with connecting PC USB port.
Please do not Charge power with the USB Hub
Please use the specified AC Adapter in this box, it might cause charge failure or
burn this device with the other adaptors.
3Power Charge Time
Full Power Charge Time will change depending on the condition how you use and
the battery status.
4There are about 300 times of Li battery charge and discharge power.
The life of Li battery will change depending on the condition how you use.
Default Setup Value
ModeReal mode Auto Power-OFF time3mins
Device nameBTS700BT last address digitals
AuthorizationNo
BT profileHID PIN Code0000
EncryptionNo Time setupOFF
RESET Back to Default Setup Value
How to reset back to Default Setup Value
When there is no way to delete the set-up values, we would like to suggest you to reset
this device back to Default Value.
Please read the setup barcode at the right side.
As the memory setup data cannot be deleted,
please try the other below way to initialize and
delete it.
When CYCLOPS II has been setup as reverse
barcode scanner, please read reverse barcode at
the right side.
Memory Initialization
Memory Initialization will delete all data and values in the memory.
Please read the barcode at the right side which can make the memory initialized.
Please note: that there is no way to get the
data back after the memory is initialized.
Simple ways to start CYCLOPS II
1Power Turn-on
Press the scan button for 3 seconds to turn on and Scan Led will light up as well.
After power is on, Scan Led will light off.
2Power Turn Off Automatically
When the system is standing-by for a period of time, it will turn off automatically
(Default: 3mins). There is no power switch on CYCLOPS II to turn off.
3RESET Back to Default Setup Value by Hand
Please press the RESET key when the power is on (it will turn off after resetting).
Only when this machine is not working well, we would suggest you can use this way
to reset.
4Bluetooth communication
Before start Bluetooth communication, please make Paring connection with the
other Bluetooth device.
PIN default code is 0000. You can easily start connection through Bluetooth Host
device and can be confirmed by the BT LED status.
Also, You can read the setup barcode to switch mode to SPP master.
5Barcode scanning
Please press the scan key to scan the Barcode.
Barcode scanning can be confirmed by the Scan LED
status. And read the setup barcode at the right side to
confirm if CYCLOPS II is able to scan.
Communication with iPadiPhone
Under the default setup, you can use HID Profile to start BT Communication with iPad
iPhone quickly. And you can also press the function key to show or hide the software
keyboard.
Detailed Setting Guide
On our below website, you can download the Detailed Setting Guide. Please carefully
read the guide to understand all detailed explanations and ways on setup.
http://www.bitatek.com.tw
Since our Setting Guide can shown on PC monitor, CYCLOPS II can read these
barcodes directly and set up accordingly So you do not have to print out this guide.
However, it will be not easy to scan the barcode because of the light reflection on
monitor or the barcode size.
Duplication of Setup data
You can easily duplicate the Setup data from one CYCLOPS II to the other CYCLOPS II
scanners. This way will provide fast and correct Setup process for multiple data
collectors.
1You can Setup the first one CYCLOPS II through scanning the Setting Guide.
2You can connect the first CYCLOPS II with the PC through USB cable to transfer
the setup data to PC (SYSTEM.CFG file).
3Then You can connect the other CYCLOPS II with PC through USB cable to
duplicate the setup data from PC.
Long term Storage
Please store this device under the dry condition (with few moisture)
When the system is under the Batch mode and keeping off for a period of long time,
it will be RESET the time after battery is without any power.
Always charge before using CYCLOPS II and Please refer to the setting guide to set
the date& time.
How to discard this device
This device is built-in with Lithium Battery and Lithium Battery is recyclable and
important resource.
If you send it back to our company, we will disassembly and recycle it. If you want to
discard this device by yourself, please remember to pull out the battery and recycle it in
the store you bought or the other related stores.
The way to disassembly:
Remove the four screw plugs out of the case screw holes and pull out the screws.
Open the case and Remove the screws to fix the battery then you can pull out the
battery.
Notice when you are disassembling :
Please tape the metal part of the battery and it will be insulated.
Specification:
Model
Cyclops II
CPU
Atmel AT91SAM9G25 400MHz
Memory
32 MB Flash ROM
The max 8,000 data files (fixed data size: 2048 Byte including
date& time ) can be saved.
128 MB SDRAM
USB
USB2.0 Full Speed
Bluetooth
Ver.2.1+EDR Class210mincluding SPP/ HID Profile
Scanner
CMOS Imager2DMotorola SE4710 soft decode
Clock function
Yes, under Batch Mode only
Power Supply
Built-in Lithium Ion battery
It will take about 2.5hrs to complete battery charge with AC
adapter and Battery life about 8 hours ( QR code 256bytes )
scan
1
I/O Interface
Micro USB-B type
AC Adapter
Input 100240VAC 50/60Hz
Output DC5V/2A, connector type: Micro USB
Operation
condition
Storage
condition
Temperature 1050 ( charging temperature 535℃)
Humidity 2085% without condensing
Temperature -2560
Humidity 595%
Free Drop
1.5m
2
drop, and 1.0 m Tumble Drop 100 Cycles
Sealing
IP level IP54
Regulatory
CE/ FCC
Dimensions
90Lm38Wmm×16Hmm
Weight
About 50g
1 One scan per Six seconds under room temperature and Bluetooth connection.
2 Free drop on concrete, 3 times per 6 surface at room temperature
Trademark
Bluetooth & Logo is belonging to Bluetooth SIG, INC Trademark.
iPadiPhone and iOS is belonging to Apple Inc. Trademark.
ALL company name or logo appearing on this document are all intellectual property
rights belonging to BITATEK CO.,LTD.
All copy rights are reserved: without any agreement of our company, that is not
allowed to copy or quote any part or all content of this document.
Rev.1.0
CYCLOPS