User Manual

9
Chart 1 EZ Adjust Capacity Adjustability
Figure 9 Handling the EZ Loader
QUICK SET-UP
The EZ Loader is complete variable in capacity and very easy to set up. Complete the installation instructions detailed
on page 8 Turn the EZ Adjust knob to the Light Weight Position and pressurize the EZ Loader to 60 psi (4.1 bar) in
the raised position. Place all or any portion of the load on the EZ Loader, then open the purge valve to release air and
set the top of the load at the desired working height. Close the purge valve nger tight. Next, turn the EZ Adjust knob
to the Medium Weight Position leaving one position for lighter loads and one position for heavier loads. For a more
detailed explanation, refer to the following set up procedure.
Note: To ensure proper operation, always add or remove air with the EZ Adjust knob in the Light Weight Position.
SET-UP PROCEDURE
The load capacity and height of the EZ Loader is initially determined by the system pressure in the raised position.
The initial pressure is completely variable and for most applications should be between 10 psi (0.7 bar) and 60 psi
(4.1 bar). An initial pressure less than the minimum stated above can be used; however, the EZ Loader will not
extend to its maximum height. In addition, to the system air pressure setting, the operator may adjust the collapsed
capacity of the EZ Loader by turning the EZ Adjust knob. For any air pressure setting, the EZ Loader has three (3)
collapsed capacity settings; Light Weight Position, Medium Weight Position and Heavy Weight Position. A capacity
change can be made at any time without the need to add or remove air and is as easy as turning the EZ Adjust knob.
The change in capacity for two (2) air pressure settings is shown below in Chart 1.