User guide
53
Table 5-2 Module Status LED Operation (MOD) –
Corresponds to the Status attribute of the
Identity Object
DeviceNet Pin Assignment
The BDS uses a micro-style 5-pin male connector. See the figure below for pin assignments.
Figure 4 DeviceNet Pin Assignment
DeviceNet Interface
Overview
DeviceNet™ is an open industrial network that is used to connect industrial I/O devices (such as sensors and limit
switches) to controllers (such as PLC’s). It is a digital, multi-drop network based on CAN (Controller Area Network)
and CIP™ (Common Industrial Protocol). DeviceNet is a very robust protocol designed to meet the strict reliability
and performance requirements of the industrial environment.
Configuration
The BDS supports the standard DeviceNet MAC ID (Node Address) and Baud Rate (Data Rate) selections. The MAC ID
and Baud Rate and be selected from the rotary switches on the front panel or through DeviceNet configuration soft-
ware. See section 3.2 for details.
All configuration data is saved in non-volatile memory.
LED Color LED State Device State Description
None Off Power Off No power applied to device.
Red Flashing Minor Fault Unrecoverable fault detected.
Solid Unrecoverable
Fault
Output error or configuration error
(recoverable fault).
Green Flashing Device
Self-Test
Normal runtime operation.
Solid Device
Operational
Device is idle or not allocated to a
master.
Pin Function Color
1Drain Bare
2V+ Red
3V- Black
4CAN_HWhite
5 CAN_L Blue