Manual
46
RF Power Range, UHF Frequency Band (470-890 MHz)
Line size Unit power
range
Measurable
Range, Fwd
Measurable
Range, Rfl
7/8” High
Med
Low
2500 - 25 W
1000 - 10 W
250 - 2.5 W
250 - 2.5 W
100 - 1 W
25 - 0.25 W
1-5/8” High
Med
Low
5000 - 50 kW
2000 - 20 W
500 - 5 W
500 - 5 W
200 - 2 W
50 - .05 W
3-1/8” High
Med
Low
Extra Low
25 - 0.25 kW
10 - 0.1 kW
2500 - 25 W
1000 - 10 W
2500 - 25 W
1000 - 10 W
250 - 2.5 W
100 - 1 W
4-1/16” and
4-1/2”
High
Med
Low
40 - 0.4 kW
15 - 0.15 kW
4000 - 40 W
4000 - 40 W
1500 - 15 W
4000 - 4 W
6-1/8” High
Med
Low
75 - 0.75 kW
30 - 0.3 kW
8000 - 80 W
7500 - 75 W
3000 - 30 W
800 - 8 W