Fiber Distributed Antenna System (Fiber DAS)
75
BIU Change History
This page shows a history of all setting changes.
Figure 73 BIU Change History
BIU Alarm configuration RF1
This page allows for certain alarm thresholds of the BIU to be changed.
Figure 74 BIU Alarm configuration
1
2
3
4
5
6
Item Description
1
Set the value in dBm that the BIU downlink output has to exceed in order to
create an alarm
2
Set the value in seconds for the amount of time that the BIU downlink
output has to be above the threshold level in order to create an alarm.
3 Enables or disables BIU threshold/high power alarm.
4
Set the value in dBm that the BIU downlink output has to drop below in
order to create an alarm.
5 Enables or disables BIU supervision/low level alarm.
6 Click Submit after entering value(s).