Operation Manual

Table Of Contents
ID Name Class Severity Unit
21 Board supply voltage high 0x0104 Error APD
Description The board voltage is too high. This is a hardware fault.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
ID Name Class Severity Unit
22 Board supply voltage low 0x0104 Error APD
Description The board voltage is too low. This is a hardware fault.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
ID Name Class Severity Unit
101 Supply voltage high 0x0104 Error APD
Description The supplied voltage is too high. This is a hardware fault.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
ID Name Class Severity Unit
102 Supply voltage low 0x0104 Warning APD
Description The supplied voltage is too low. This is a hardware fault.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
ID Name Class Severity Unit
103 Driver voltage high 0x0104 Error APD
Description The driver voltage is too high. This is a hardware fault.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
Troubleshooting
144