Operation Manual

Table Of Contents
ID Name Class Severity Unit
2 EEPROM fault 0x0100/0x0101 Error PA
Description
The memory chip on the board is malfunctioning. This is a hardware failure.
There is a risk the RF output is not working.
NOC Actions Dispatch field tech to replace the unit as soon as possible.
Field Actions Replace failed unit.
ID Name Class Severity Unit
3
Calibration database
corrupt
0x0100/0x0101 Warning PA
Description
The calibration database has been corrupted on the board. It is likely there is a
hardware problem.
NOC Actions Dispatch field tech to replace the unit as soon as possible.
Field Actions Replace failed unit.
ID Name Class Severity Unit
11 Temperature high 0x0100/0x0101 Warning PA
Description The PA has detected a temperature above 95° C (203° F) internally.
NOC Actions
Turn unit RF off to prevent overheating if alarm persists. Dispatch field tech to
examine environment.
Field Actions
Examine environment, arrange for better air circulation. If outdoor consider
adding the sun shield that goes over the cooler.
ID Name Class Severity Unit
11 Temperature high 0x0100/0x0101 Error PA
Description The PA has detected a temperature above 95° C (203° F) internally.
NOC Actions
Turn unit RF off to prevent overheating if alarm persists. Dispatch field tech to
examine environment.
Field Actions
Examine environment, arrange for better air circulation. If outdoor consider
adding the sun shield that goes over the cooler.
ID Name Class Severity Unit
12 Temperature low 0x0100/0x0101 Warning PA
Description
Measured temperature is low. Generally this may happen after a power failure
in a very cold location.
NOC Actions
Give the unit an hour to warm up after power returns, if alarm is not clearing of
its own give the unit a reset.
Field Actions Same as for NOC.
Fiber Distributed Antenna System (Fiber DAS)
137