User's Manual
Manual 7-9386-1 Page 24TX RX Systems Inc. 09/30/04
61-68-50 UserMan page 24 of 25
Part Number 61-70-50-A2.0-G1 61-71-50-A0.5-G1 61-72-50-A0.5-G1
Maximum Gain:
+80 dB +80 dB +80 dB
Gain Adjustment:
Programmable attenuation,
0-30 dB, 0.5 dB steps
Programmable attenuation,
0-30 dB, 0.5 dB steps
Programmable attenuation,
0-60 dB, 0.5 dB steps
3rd Order Output Intercept Point:
+50 dBm minimum,
with no attenuation
+50 dBm minimum,
with no attenuation
+50 dBm minimum,
with no attenuation
Max RF Power Output
+32 dBm (single carrier) +32 dBm (single carrier) +32 dBm (single carrier)
RF Sampler:
PA Output sampler ports PA Output sampler ports PA Output sampler ports
Noise Figure (without attenuation):
5.0 dB maximum 8.0 dB maximum 8.0 dB maximum,
Operating Temperature Range:
-30°C to +50° C -30°C to +50° C -30°C to +50° C
Nominal Impedance:
50 ohms, <1.5:1 VSWR 50 ohms, <1.5:1 VSWR 50 ohms, <1.5:1 VSWR
Input/Output Connectors:
N female N female N female
RF Sampler Connectors:
BNC female BNC female BNC female
AC Power Input:
100-240 VAC; 50-60 Hz 100-240 VAC; 50-60 Hz 100-240 VAC; 50-60 Hz
DC Input Voltage:
+24 to +30 VDC +24 to +30 VDC +24 to +30 VDC
Unit Power Consumption (AC/DC):
<100 VA <100 VA <100 VA
Housing:
NEMA 4, NEMA 4X
Rack Mount
NEMA 4, NEMA 4X
Rack Mount
NEMA 4, NEMA 4X
Rack Mount
Nominal Size:
36" x 30" x 12" 30" x 24" x 12" 30" x 24" x 12”
Net Weight:
< 100 lbs. < 100 lbs. < 100 lbs.