User's Manual
EXHIBIT 2 PAGE 10 OF 17
TX RX Systems Inc. Manual 7-9257 (version 1) 11/03/00 Page 10
power supply assembly is functioning normally.
The red LED is not used.
PERFORMANCE SURVEY
It is a good idea to document the performance of
the system after installation so that a reference
exists for future comparisons. This information can
make troubleshooting an interference problem or
investigation of a complaint about system perfor-
mance much easier. If there are coverage prob-
lems with a system, this survey will usually reveal
them allowing corrective measures to be taken
before the system is put into routine use. The fol-
lowing is an outline of how to do such a survey.
Because the nature of each installation can be
quite different, only a broad outline is given.
1) Measure the gain of the signal booster being
careful not to exceed the maximum input level.
Figure 4 shows this being done using a signal
generator and spectrum analyzer. This is basi-
cally a substitution measurement. Record the
measured values for each passband.
2) The signal booster system is equipped with a -
50 dB signal sampler port following the final out-
put amp (part of the OLC assembly). This port
is for the connection of test equipment such as
a spectrum analyzer and will allow the observa-
tion of the amplifier output at a considerably
reduced output level. This decoupling figure
needs to be added to a measured signal value
in order to arrive at the actual signal level.
3) With a spectrum analyzer connected to the sig-
nal sampler port (see figure 5), have personnel
with handheld radios move to predetermined
points and key their radios. Record the level of
these signals as observed on the analyzer and
also record the location of the person transmit-
ting. In this way, a map of the systems perfor-
mance can be generated.
4) For branches that amplify signals coming from a
fixed antenna or station, record the level of all
the desired incoming signals for future refer-
ence.
MAINTENANCE AND REPAIR
Signal boosters manufactured by TX RX Systems,
Inc. can function reliably for 10 or more years with
little or no maintenance. However, if the amplifiers