User's Manual

36
20.1 Lay-out
Numerical keys to
1 9
Battery compartment
Infrared interface
Function keys to
A F
Locking screw
Start key
G
Front Rear
20.4 Addressing the sensor
Four different addresses for communicating with the Reglo-
beam can be set at the sensor.
Different methods of addressing the sensors must be used
in the two cases below:
a)
Several sensors are located within range of remote con-
trol unit. This can occur with sensors which are located
next to each other, but also with sensors located oppo-
site each other (e.g. at draught-proof door applications).
Choose different addresses
Make the connection between the sensor
and remote control unit as per section 20.5.
b)
Several sensors are installed next to each other,
whereby their AIR detection areas overlap.
The sensor addresses must be chosen in such a
way that in each case an odd address (1 or 3) is
located next to an even (2 or 4) address, otherwise
there will be interference between the AIR detec-
tion areas.
Make the connection between the sensor
and remote control unit as per section 20.5.
Address 1*
Address 2
Address 3
Address 4
*
Factory default setting
If no keys light up on the Reglobeam,
replace the batteries.
If and one of the keys to light up,
but no further settings are possible,
then configuration mode is not activated.
Activate configuration mode
(section 20.2)
Press start key located on the Reglobeam.
If the connection has been made successfully,
and one of the keys to lights up
(see also section 20.4 for sensor address).
No connection could be established if
flashes.
Hold the remote control unit closer
and aim it at the sensor.
Check the batteries in the Reglobeam.
G
G 1 4
1
4
G
G
Address selector switch
20.3 Making the connection
There are three different ways of
activating configuration mode:
a)
Press either of the
or control keys located on the sensor
or
b)
Restart the sensor
(disconnect the supply voltage)
or
c)
Gain access to configuration mode via an access code
(see chapter 21ff)
20.2 Configuration mode
X
Y
A connection between the Reglobeam and the sensor can
only be established if the sensor is in configuration mode.
Configuration mode is activated after the sensor has been
switched on. For safety reasons this mode is automatically
deactivated 30 minutes after the last setting has been made
at the sensor.
X
Y
Control key
Control key
Control keys
Configuration mode can be deactivated at any time with the
following function:
+ + =
Deactivate configuration mode
1 3A