User's Manual
24
9
Mechanical settings of the radar field
Range: 0° to 90°, adjustable in 30° steps
Factory setting: approx. 30°
9.1 Tilting the radar detector
Radar detector
Radar field
+
–
Field without clip
Mounting the clip
Field with clip
The clip can only be used for mounting heights
up to 4 m (13.1 ft). The field geometry is altered
using the clip. The operating voltage must be
interrupted for at least 5 seconds every time the
clip is put on or removed.
The wide field must be activated using the key combination
+ after the clip is fitted. Refer to section 7.9.
9.2 Detection field geometry (clip)
Important:
Fit the clip correctly
Check that the field settings are correct by pacing across the
detection field and observing the corresponding LED. Refer
to page 26 ff. for field dimensions.
10
Testing the field settings
General functions
11
Manual industrial door opening
+ =
Switch on relay
+ =
Switch off relay
Manual industrial door opening remains active for max. 15 minutes unless the function is switched off again.
Then the industrial door closes and automatic mode is reactivated.
1A
2A
13
Reset
12
Access code
Please see chapter 6.
1
2
3
Separation between
Direction
LED people and vehicles recognition
switched ON
Red Detecting people Forwards recognition
Green Detecting vehicles Backwards recognition
1B
There are two ways of resetting the unit back
to factory default:
a)
using the remote control unit
+ = reset
or
b)
using the push-buttons
Press and simultaneously for 8 seconds.
Both LEDs light up briefly every two seconds.
9A
X
Y
This function resets all the sensor’s parameters to the factory
default settings (see page 25, “Overview of remote control
unit functions”) and a new initialisation phase begins when
the unit is switched on (see chapter 4).
Furthermore, the access code is cleared when the system is
reset (chapter 6ff).
+
–