User's Manual

Motion detector settings
Refer to chapter 8ff for programming without the remote control unit.
The table on page 25 provides an overview of all functions with values and factory settings.
Notes
– Remote control unit: see chapter 5ff for Reglobeam functions
– Programming must be carried out within 30 s, otherwise you will have to restart the process
7
Programming using the remote control unit
7. 1 Mounting height
+ +
(levels 2 to 7)
2 = 2.50 to 2.90 m (8.2 to 9.5 ft)
3 = 3.00 to 3.90 m (9.8 to 12.8 ft)
4 = 4.00 to 4.90 m (13.1 to 16.1 ft)
etc.
4 2 7F
21
+
Levels 1 (small field) to 9 (large field)
Refer to page 26–27 for field dimensions.
7. 3 Field size (sensitivity)
D 1 9
The mounting height must always be entered
(factory setting 4.00–4.90m, 13.1–16.1 ft).
7. 4
Relay hold interval (additional hold interval)
+ +
(levels 1 to 4)
1 = 0.5 s
2 = 1.0 s
3 = 2.0 s
4 = 5.0 s
1 1 4F
The additional hold interval only starts after other functions
have taken place with delayed effect.
These pre-programmed settings are designed for quick and
easy configuration in the case of standard applications.
+ = Standard, detects all objects
+ = Frontal traffic, all objects
+ = Lateral traffic, all objects
+ = High sensitivity, all objects
+ =
Standard, P/ V separation
1
+ = Frontal traffic, P/ V
separation
1
+ = Lateral traffic, P/ V
separation
1
+ = High sensitivity, P/ V
separation
1
1
Separation between people and vehicles
Remote control unit can only read back and display comfort
functions correctly if all the parameters still correspond to
the preprogrammed values. If individual functions are adjusted,
only key lights up on the remote control unit.
The pre-programmed values of the enhanced functions are
shown in the enhanced functions” overview table on page 26.
7. 2 Comfort functions
1C
2C
3C
4C
5C
6C
7C