User's Manual
5.3 Making the connection
19
5.1
Lay-out
Numerical keys to
1 9
Battery compartment
Infrared interface
Function keys to
A F
Locking screw
Start key
G
There are three different ways of
activating configuration mode:
a)
Press either of the
or push-buttons located on the sensor
or
b)
Restart the sensor
(disconnect the supply voltage)
or
c)
Gain access to configuration mode via an access code
(see chapter 6ff)
5.2 Configuration mode
X
Y
A connection between the Reglobeam and the Herkules can
only be established if the sensor is in configuration mode.
Configuration mode is activated after the sensor has been
switched on. For safety reasons this mode is automatically
deactivated 30 minutes after the last setting has been made
at the sensor.
X
Y
Push-button
Push-button
Front Rear
5.4 Addressing the sensor
Four different addresses for communicating with the Reglo-
beam can be set at the sensor.
Different methods of addressing the sensors must be used
in the two cases below:
Several sensors are located within range of remote con-
trol unit. This can occur with sensors which are located
next to each other, but also with sensors located oppo-
site each other.
➔
Choose different addresses
➔
Make the connection between the sensor
and remote control unit as per section 5.3.
Address 1*
Address 2
Address 3
Address 4
*
Factory default setting
Address dip switch
➔
If no keys light up on the Reglobeam,
replace the batteries.
➔
If and one of the keys to light up,
but no further settings are possible,
then configuration mode is not activated.
➔
Activate configuration mode
(section 5.2)
Press start key located on the Reglobeam.
➔
If the connection has been made successfully,
and one of the keys to lights up
(see also section 5.4 for sensor address).
➔
No connection could be established if
flashes.
➔
Hold the remote control unit closer
and aim it at the sensor.
➔
Check the batteries in the Reglobeam.
G
G 1 4
1 4
G
G