User's Manual
18
4
Switch-on and initialisation
The unit is ready for setting when the supply voltage has been
connected, once the green LED has flashed several times.
The default setting is suitable for the following
applications:
– Mounting height 4.00 to 4.90 m (13.1 to 16.1 ft)
– Relay hold interval 2 s, output active
– Slow motion detection on medium level (detection of very slow
objects)
– Separation between people and vehicles active
– Crossing traffic masking on medium level
– Detection of movements towards the detector (forwards)
If other settings are required, then they can be changed using the
remote control or with the push-buttons. Refer to chapter 8 for
information about setting with push-buttons.
The Reglobeam is operated via a combination of function and
numerical keys. Note the correct method of operation as per
chapters 5ff and 7ff.
Flashing keys on the Reglobeam mean that data transfer was
incomplete. The infrared interface should not be exposed to
direct sunlight and other light sources.
The Reglobeam remote control unit allows you to program
the Herkules easily and conveniently from floor level. Data
transfer between the Reglobeam and the Herkules takes place
in both directions, i.e. to and from the sensor; it is ensured by
an infrared interface. The set values are read back by the
Reglobeam immediately after programming, and are displayed
so that they can be checked. This ensures a safe and correct pro-
gramming.
5
Function
Reglobeam remote control unit
Field dimension with mounting angle 30°
D6
3 2.5 2 1.5 1 0.5 0 0.5 1 1.5 2 2.5 3
9.8' 8.2' 6.6' 4.9' 3.3' 1.6' 0 1.6' 3.3' 4.9' 6.6' 8.2' 9.8'
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
6
1.6'
3.3'
4.9'
6.6'
8.2'
9.8'
11.5'
13.1'
14.8'
16.4'
18.0'
19.7'
3.1 Pin assignment
3
Electrical connection
If the industrial door control only has one relay input, it is
possible to connect whichever of the signals is required.
48 V AC / DC
55 VA / 24 W
55 VA / 24 W
48 V AC / DC
Person
Vehicle
white
brown
green
yellow
grey
pink
blue
red
1
2
3
4
5
6
7
8
12–28 V AC / 12–36 V DC
12–28 V AC / 12–36 V DC
48 V AC / DC
55 VA / 24 W
55 VA / 24 W
48 V AC / DC
Forward
Backwards
white
brown
green
yellow
grey
pink
blue
red
1
2
3
4
5
6
7
8
12–28 V AC / 12–36 V DC
12–28 V AC / 12–36 V DC
Connection when separation between people
and vehicles switched ON
Connection for direction recognition
Separation between people and vehicles switched OFF
Meters