NOTICE This device complies with part 15 of the FCC Rules. Operation is subject to the following two condition: (1) This device may not cause harmful interface, and (2) This device must accept any interface received, including Interface that may cause undesired operation. This equipment has been tested and found comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
Operation Manual 2
Index 1 Instroduction«««««««««««««««««««««««««««««««««««««««««««««««« 4 Installation ««««««««««««««««««««««««««««««««««« 4 Recommended Steps «««««««««««««««««««« 4 Configuration Flowchart««««««««««««««««« 5 String Output Flowchart«««««««««««««««««« 5 Default Setting««««««««««««««««««««««««««««« 6 Manual Label Layout««««««««««««««««««««« 7 Frequent Question «««««««««««««««««««««««« 8 2 Interface««««««««««««««««««««««««««««««««««««««««««««««««««««««« 10 Host Interface«««««««««««««««««««««««««««««« 10 Keyboard
Installation 1) First of all, you must make sure that the power is disconnected form your equipment before connecting the scanner. Beside, you also have to check the cable connector of the scanner match your equipment interface correctly. 2) Boot up your computer after connecting the scanner with your equipment, the scanner will make a long music and light the LED, above scanner to indicate a successful power on. Trigger the button, the scan line in front of scanner will active.
Configuration Flowchart Set ASCII Code Hexdecimal (High Byte) Prefix or Suffix Hexdecimal Only (Low Byte) Set Decimal Value Decimal (10's Value) Decimal (1's Value) Finish ASCII Code or Decimal Value Setting SET EXIT Exit With Save ABORT Exit Without Save DEFAULT Exit & Default VERSION DATE Exit & Version List SETTING LIST Exit & Setting List Interface Default Exit & Interface Default String Output Flowchart Preamble Prefix Code Name Code ID Code Length Code Data Suffix Postamble 5 Introduc
Default Setting Code Read Length Truncate Code Type Enable Min. Max.
Manual Label Layout Exit Program Function Title EXIT */$%END* UPC-A Truncate Leading Zero Group Line Disable DZA Enable DZB Selection Label *DZA* *DZB* Default Setting Spare Function Disable DYA Enable DYB Selection Description *DYA* Function Description *DYB* Adjustment (ASCII Code or Decimal Value) Specific Adjustments *BAO* (Range:00 1 0 -15 1 0 ) Truncate Ending BAP *BAP* (Range:00 1 0 -15 1 0 ) Code ID AAA *AAA* (Range:00 1 6 -FF1 6 ASCII Code) Code Option Code ID: A C o
Frequent Question Q: Why scanner block the keyboard operation? A: Check the cable connection with your equipment, then turn power on again. Q: If scanner has a good read beep but nothing transferring after read a label. A: Using the S ETTING LIST at /10 to show what current setting of scanner is, or reset to Default, (or select right Interface default if scanner to be change another interface used), then re-program scanner again.
Example Beep Loudness Level "10", Good-read Beep "Enable" To configure the reguired commands proceed as follows: Send as: (1B16) ï Command(s) ï (0D16) Send ï BACï %01ï %00ï %OKï CEBï ︸ ︸ ︸ ︸ ︸ Beep 1 0 SET Good-read Londness Level Beep Enable * Call to the dealer if scanner dose not work properly. 9 Introduction Q: How to configure scanner via RS-232C? A: Next to the selection description, you will find a frame command, such as AAB.
PROGRAM */$%STR* Host Interface Interface Default Keyboard Wedge */$%C00* RS-232C */$%C01* WAND EMULATION */$%C02* You can change factory interface default for other type interface. By plug different cable, program scanner and set right interface to exit, then the scanner will be change to another interface. However, you must make sure what cable you need. Refer Cable Type to /66, 67.
EXIT Keyboard Wedge */$%END* Keyboard Speed Low CZA Medium CZB High CZC Turbo CZD *CZA* *CZB* *CZD* Function Key Simulation Set E nable scanner can output code as pressing function-key in your application program while the barcode datas contain ASCII value between 0116 to 1F16.. See /60 and Refer to ASCII table /71 at grey area. You'll find function-keys with ASCII codes.
PROGRAM */$%STR* Keyboard Wedge Keyboard Simulation Disable DCA *DCA* Enable DCB *DCB* All of the PCs check the keyboard status during power-on selftest. It is recommended to E nable the function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on. Spare Function Disable DEA *DEA* Enable DEB *DEB* Specific Adjustments Inter-char.
EXIT Keyboard Wedge */$%END* Keyboard Type Select keyboard type connector of your host computer. Scanner must be selected to the appropriate host interface cable converter. Refer to Cable Type at /66. IBM AT,PS/2 DFA IBM XT DFB Macintosh ADB.
PROGRAM */$%STR* Keyboard Wedge Keyboard Layout DGA USA (US) *DGA* DGB Belgium (BE) *DGB* DGC Danish (DK) *DGC* DGD France(FR) *DGD* DGE The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country langage that you desire. In DOS, using command "Keyb" to selecte the desirable keyboard layout or in WINDOWS entry "Control' then pop "Keyboard" to selecte country at "language" item.
EXIT */$%END* RS-232C Handshaking Protocol CTS: Clear To Send (Hardware Signal) RTS/CTS DLB CTS/RTS DLC Scanner Ready DLD Data Ready DLE Xon/Xoff DLF STX/ETX DLG CTS Trigger DLH Spare DLI *DLA* Xon: Transmit On Xoff: Transmit Off *DLB* (ASCII Code 1316) (ASCII Code 1116) Disable: The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol.
PROGRAM */$%STR* RS-232C Baud Rate DHA 38400 Bps *DHA* DHB 19200 Bps *DHB* DHC 9600 Bps *DHC* DHD 4800 Bps *DHD* DHE 2400 Bps *DHE* DHF 1200 Bps *DHF* DHG 600 Bps *DHG* DHH 300 Bps *DHH* Data Parity DKA None *DKA* DKC Even *DKC* DKD Odd *DKD* DKE Space *DKE* DKF Mark *DKF* Operation Manual 16
EXIT */$%END* RS-232C Data Bits 7 Bits DJA 8 Bits DJB *DJA* *DJB* 2 Stop Bits DIA Two Bits DIB *DIA* *DIB* Specific Adjustments Inter-char. Delay: It is delay time between data character's output. It is same as I nter-char. Delay of keyboard wedge, see /12. Transmit Delay: It is a delay time between barcode data output. It is also same as Transmit Delay of Keyboard wedge, see /12. Inter-char.
PROGRAM */$%STR* Wand Emulation Active Level DMA Bar Hi/Space Lo *DMA* DMB Bar Lo/ Space Hi *DMB* Bar Hi/Space Lo: Black will be transmited as a high voltage level (+5V) and space as low level (0V). Bar Lo/Space Hi: Black will be transmited as a low voltage level (0V) and space as high level (+5V). Normal Level DNA Low *DNA* DNB High *DNB* You must make sure what is Normal Level of your wand decoder device in stand-by (idle).
EXIT Wand Emulation */$%END* Inter-char. Gap Narrow DPA Wide DPB *DPA* *DPB* Code-39 Simulation Disable DRA Enable DRB *DRA* *DRB* Specific Adjustments Margin Delay: It is a timer of zone like space zone of barcode label margin. The width of margin time will be added before and after in each barcode data automatically when it is transmitted.
PROGRAM */$%STR* OCIA Protocol Type DSA NCR *DSA* DSB DTS *DSB* DSC NCR+ASCII *DSC* DSD DTS+ASCII *DSD* DSE ASCII *DSE* Data Parity DTA Even *DTA* DTB Odd *DTB* DTC Space *DTC* DTD Mark *DTD* Spare Function DUA Disable *DUA* DUB Enable *DUB* Specific Adjustments BAM Transmit Delay *BAM* (Range:0010-9910 Unit:10ms) Operation Manual Tansmit Delay: It is a delay time between barcode data output. It is also the same as Transmit Delay of keyboard wedge, see /12.
EXIT System Control */$%END* Power-on Music After power-on the scanner will generate music to indicate the successful selftest. You can inhibit the music by setting D isable . Disable CBA Enable CBA *CBA* *CBB* Power-on Auto Trigger By setting E nable , the scanner will activate the light source after the power-on without trigger button.
PROGRAM */$%STR* System Control Double Confirm CSA Disable *CSA* CSB Enable *CSB* The scanner will require many times of successful decoding to confirm the barcode data, and the more confirm times the more inhibitive mis-reading code. (Refer to setting of D oubble Confirm Times at /25) Case Conversion CTA Disable *CTA* CTC Uppercase *CTC* CTD Lowercase *CTD* It converses all output characters to be same printing-case, even they have two kinds of case within a barcode data.
EXIT System Control */$%END* Scanning Mode Good-read Off: The trigger button must be pressed to active scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the S tand-by Timer /24 duration elapsed. (Laser Model Default) Momentary: The trigger button acts as a switch. Press button to active scanning and release button stop scanning.
PROGRAM */$%STR* System Control Specific Adjustments BAC Beep Loudness *BAC* (Range:0110-1010 Unit:Level) BAD Beep Tone *BAD* (Range:0510-5010 Unit:100Hz) BAE Beep Duration *BAE* (Range:0110-9910 Unit:10ms) BDA Beep Tone1 *BDA* (Range:0510-5010 Unit:100Hz) BDB Beep Duration1 *BDB* (Range:0010-9910 Unit:10ms) Stand-by Time BAF *BAF* (Range:0110-9910 Unit:1s) BAG Active Time *BAG* (Range:1010-9910 Unit:10ms) BAH Beep Adjustments: You can adjust B eep Loudness , B eep Tone and B
EXIT System Control */$%END* Specific Adjustments Add-on Waiting Time: This setting is Addon-Waiting Time BAK only used for reading WPC symbologies with Add-on, such as (Range:0110-9910 Unit:10ms) EAN and UPC. The WPC must be decoded first, then Add-on. But Add- Double Confirm Times BAJ on may not decode very well during it read. Therefore, scanner offer a (Range:0110-9910) waiting time for reading Add-on confirmation and transmits WPC with Public Min. Length BAA Add-on at the same time.
PROGRAM */$%STR* UPC-A Read Disable DVA Format *DVA* Leading Data Digts Check Zero (11 Digits) Digit Enable DVB *DVB* Add-on DWA Disable *DWA* DWB Add-on 2 Only *DWB* DWC Add-on 5 Only *DWC* DWD The Add-on barcode is the supplemental 2 or 5 characters for WPC code.
EXIT */$%END* UPC-A Truncate Leading Zero The leading "0" digits of barcode data characters can be truncated when the function is enabled.
PROGRAM */$%STR* UPC-E Read ECA Disable Format *ECA* ECB Leading Data Digits Check Zero (6 Digits) Digit Enable *ECB* Add-on EDA Disable Format *EDA* EDB Leading Data Digits Check Add-on Zero (6 Digits) Digit 2 or 5 Add-on 2 Only *EDB* EDC Add-on 5 Only *EDC* EDD Add-on 2 or 5 *EDD* Waiting Add-on EEA Disable Refer to /26. *EEA* EEB Enable *EEB* Expansion EFA Disable *EFA* EFB Enable The expansion function is used only for UPC-E and EAN-8 code reading.
EXIT */$%END* UPC-E Check Digit Transmission Refer to /26. Disable EIA Enable EIB *EIA* *EIB* Truncate Leading Zero Refer to /27. Disable EHA Enable EHB *EHA* *EHB* Spare Function Enable EGB *EGA* *EGB* Specific Adjustments Refer to /27.
PROGRAM */$%STR* EAN-13 Read Disable EKA Format *EKA* Data Digts Check (12 Digits) Digit Enable EKB *EKB* Add-on Disable ELA Format *ELA* Data Digits Check Add-on (12 Digits) Digit 2 or 5 Add-on 2 Only ELB *ELB* Add-on 5 Only ELC *ELC* Add-on 2 or 5 ELD *ELD* Waiting Add-on EMA Disable Refer to /26.
EXIT */$%END* EAN-13 Check Digit Transmission Refer to /26. Disable EQA Enable EQB *EQA* *EQB* Truncate Leading Zero Refer to /27. Disable EPA Enable EPB *EPA* *EPB* Spare Function Enable EOB *EOA* *EOB* Specific Adjustments Refer to /27.
PROGRAM */$%STR* EAN-8 Read ESA Disable Format *ESA* ESB Data Digits Check (7 Digits) Digit Enable *ESB* Add-on Disable ETA Format *ETA* Data Digits Check Add-on (7 Digits) Digit 2 or 5 Add-on 2 Only ETB *ETB* Add-on 5 Only ETC *ETC* Add-on 2 or 5 ETD *ETD* Waiting Add-on EUA Disable Refer to /26. *EUA* EUB Enable *EUB* Expansion EVA Disable Refer to /28.
EXIT */$%END* EAN-8 Check Digit Transmission Refer to /26. Disable EY A Enable EY B *EYA* *EYB* Truncate Leading Zero Refer to /27 Disable EXA Enable EXB *EXA* *EXB* Spare Function Enable EWB *EWA* *EWB* Specific Adjustments Refer to /27.
PROGRAM */$%STR* CODE-39 Read FAA Disable *FAA* FAB Enable Format Start Data Digits Checksum End "V " (Variable) (Optional) "V " *FAB* Format FBA Standard *FBA* FBB Full ASCII *FBB* The F ull ASCII Code-39 is an enhanced set of Code-39 that is the data with toatl of 128 characters to represent F ull ASCII code. It is combined one of the digits +,%,$ and / with one of the alpha digits (A to Z).
EXIT */$%END* CODE-39 Checksum Verification The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Disable FGA Enable FGB *FGA* *FGB* Checksum Transmission By setting E nable , checksum and will be transmitted. Disable FHA Enable FHB *FHA* *FHB* Specific Adjustments *BAY* (Range:0010-1510) Truncate Ending BAZ *BAZ* (Range:0010-1510) Min. Code Length BAW *BAW* (Range:0110-5610) Max.
PROGRAM */$%STR* Interleaved 2 of 5 Read FKA Disable Format *FKA* FKB Data Digits Checksum (Variable) (Optional) Enable *FKB* Format Standard FLA *FLA* Odd S-code FLB *FLB* Generally, the Interleaved 2 of 5 symbology is a pair of digts in each barcode. Therefore, it contains an even digits. If the symbol is present an odd number as S-code, then O dd S-code have to select.
EXIT Interleaved 2 of 5 */$%END* Specific Adjustments Because, the start and end of interleaved 2 of 5 code is not olny one patten in symbol. In order to prevent partial reading, it is recommand to use the fixed code length for each 2 of 5 code barcode label. Setting the same Min./Max. Code Length, it is like a length filter, and only one length is accepted. Truncate Leading BBC *BBC* (Range:0010-1510) Truncate Ending BBD *BBD* (Range:0010-1510) Min. Code Length BBA *BBA* Refer to /27, /35.
PROGRAM */$%STR* Industrial 2 of 5 Read FQA Disable Format *FQA* FQB Data Digits Checksum (Variable) (Optional) Enable *FQB* Checksum Verification FSA Disable *FSA* FSB The checksum is made as the sum module 10 of the numberical values of all data digits. Enable *FSB* Checksum Transmission Disable FTA Refer to /35.
EXIT Industrial 2 of 5 */$%END* Specific Adjustments Refer to /27, /35. Truncate Leading BBG *BBG* (Range:0010-1510) Truncate Ending BBH *BBH* (Range:0010-1510) Min. Code Length BBE *BBE* (Range:0010-5610) Max.
PROGRAM */$%STR* Matrix 2 of 5 Read FVA Disable Format *FVA* FVB Data Digits Checksum (Variable) (Optional) Enable *FVB* Checksum Verification Disable FXA *FXA* The checksum is made as the sum module 10 of the numberical values of all data digits. Enable FXB *FXB* Checksum Transmission FY A Disable Refer to /35.
EXIT */$%END* Matrix 2 of 5 Specific Adjustments Refer to /27, /35. Truncate Leading BBK *BBK* (Range:0010-1510) Truncate Ending BBL *BBL* (Range:0010-1510) Min. Code Length BBI *BBI* (Range:0010-5610) Max.
PROGRAM */$%STR* China Post 2 of 5 Read GAA Disable Format *GAA* GAB Data Digits Checksum (Variable) (Optional) Enable *GAB* Checksum Verification GCA Disable *GCA* GCB The checksum is made as the sum module 10 of the numberical values of all data digits. Enable *GCB* Checksum Transmission GDA Disable Refer to /35.
EXIT China Post 2 of 5 */$%END* Specific Adjustments The code length of Post 2 of 5 is Truncate Leading BBO always fixed at 11. Therefore, code length of Min. and Max. is also factory (Range:0010-1510) default is 11. Truncate Ending BBP Refer to /27, /35. *BBO* *BBP* (Range:0010-1510) Min. Code Length BBM *BBM* (Range:0010-5610) Max.
PROGRAM */$%STR* GFA Read Disable *GFA* GFB Enable Codabar/NW7 Format Start Data Digits Cheksum End (Variable) (Optional) *GFB* Start/End Symbol Types GGA ABCD/ABCD *GGA* GGB The Codabar has four pairs of Start/End patten, you may choice one to match your application. abcd/abcd *GGB* GGC ABCD/TN*E *GGC* GGD abcd/tn*e *GGD* Same Start/End Pair GHA Disable *GHA* GHB Sometime, the Codabar requires only same Start/End patten of barcode label to be decoded.
EXIT */$%END* Codabar/NW7 Checksum Transmission Refer to /35. Disable GKA Enable GKB *GKA* *GKB* Specific Adjustments Refer to /27, /35. Truncate Leading BBS *BBS* (Range:0010-1510) Truncate Ending BBT *BBT* (Range:0010-1510) Min. Code Length BBQ (Range:0010-5610) *BBR* (Range:0010-5610) Code ID AAL *AAL* (Range:0016-FF16 ASCII Code) Insertion Group BDL *BDL* (Range:0010-9910) 45 Code Option Max.
PROGRAM */$%STR* Code-128 Read GMA Disable Format *GMA* GMB Data Digits Checksum (Variable) (Optional) Enable *GMB* Format GNA Standard *GNA* GNB UCC/EAN-128 *GNB* The Code-128 can be translated to U CC/EAN-128 format if it starts with FNC1 character. The first FNC1 will be translated to "]C1", and next to be a concatenation code as (7F16).
EXIT */$%END* Code-128 Spare Function Disable GPA Enable GPB *GPA* *GPB* Specific Adjustments Concatenation Data: This featrure is only used for UCC/EAN-128 format. This C oncatenation Data means you can re-assign second or after a FNC1 for your usage. The default of ASCII code is (1D16). Truncate Leading BBW *BBW* (Range:0010-1510) Truncate Ending BB X *BBX* (Range:0010-1510) Refer to /27, /35. Min.
PROGRAM */$%STR* Code-93 Read GTA Disable *GTA* GTB Enable Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) *GTB* Append GVA Disable *GVA* GVB This function which allows several symbols to be concatenates and be treated as one single data entry. Enable *GVB* Checksum Verification GWA Disable *GWA* GWC The checksum is presented as the sum module 47 of all data digits. One *GWC* GWD Two *GWD* Checksum Transmission GXA Disable Refer to /35.
EXIT */$%END* Code-93 Specific Adjustments Refer to /27, /35. Truncate Leading BCA *BCA* (Range:0010-1510) Truncate Ending BCB *BCB* (Range:0010-1510) Min. Code Length BBY *BBY* (Range:0010-5610) Max.
PROGRAM */$%STR* Code-11 Read GZA Disable *GZA* GZB Enable Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) *GZB* Checksum Verification HBA Disable *HBA* HBC The checksum is presented as the sum module 11 of all data digits. One *HBC* HBD Two *HBD* Checksum Transmission HCA Disable *HCA* HCB Enable By setting E nable , checksum1 and checksum2 will be transmitted upon your selected checksum verificvation mothod.
EXIT */$%END* Code-11 Specific Adjustments Refer to /27, /35. Truncate Leading BCE *BCE* (Range:0010-1510) Truncate Ending BCF *BCF* (Range:0010-1510) Min. Code Length BCC *BCC* (Range:0010-5610) Max.
PROGRAM */$%STR* MSI/Plessey Read HEA Disable *HEA* HEB Enable Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) *HEB* Checksum Verification HGA Disable *HGA* HGB Mod 10 *HGB* HGC Mod 10/10 The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of mothod Mod 10 , Mod 10/10 and Mod 11/10 . The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits.
EXIT */$%END* MSI/Plessey Specific Adjustments Refer to /27, /35. Truncate Leading BCI *BCI* (Range:0010-1510) Truncate Ending BCJ *BCJ* (Range:0010-1510) Min. Code Length BCG *BCG* (Range:0010-5610) Max.
PROGRAM */$%STR* UK/Plessey Read HQA Disable Format *HQA* HQB Data Digits Checksum1+2 (Variable) (Optional) Enable *HQB* Checksum Verification HSA Disable *HSA* HSB Enable *HSB* Checksum Transmission Disable HTA Refer to /35.
EXIT */$%END* UK/Plessey Specific Adjustments Refer to /27, /35. Truncate Leading BCQ *BCQ* (Range:0010-1510) Truncate Ending BCR *BCR* (Range:0010-1510) Min. Code Length BCO *BCO* (Range:0010-5610) Max.
PROGRAM */$%STR* IATA Read HJA Disable *HJA* HJB IATA (International Air Transport Association) Enable *HJB* Checksum Verification HNA Disable *HNA* HNB The checksum is presented as sum module 7 of all data digits. Enable *HNB* Checksum Transmission HOA Disable Refer to /35.
EXIT */$%END* IATA Specific Adjustments Refer to /27, /35. Truncate Leading BCM *BCM* (Range:0010-1510) Truncate Ending BCN *BCN* (Range:0010-1510) Min. Code Length BCK *BCK* (Range:0010-5610) Max.
PROGRAM */$%STR* Telepen Read HVA Disable Format *HVA* HVB Data Digits Checksum (Variable) (Optional) Enable *HVB* Format HWA Numeric Only *HWA* HWB Full ASCII Only *HWB* HWC Auto Switching *HWC* A Telepen can be transimtted with and F ull ASCII format. Characters can be mixed both formats inside barcode label of Telepen. By setting A uto Switching , datas can be conversed between Numeric and Full ASCII by character (7F16) automatically.
EXIT */$%END* Telepen Specific Adjustments Refer to /27, /35. Truncate Leading BCU *BCU* (Range:0010-1510) Truncate Ending BCV *BCV* (Range:0010-1510) Min. Code Length BCS *BCS* (Range:0010-5610) Max.
PROGRAM */$%STR* Preamble/Postamble Preamble Transmission Disable IEA *IEA* Enable IEB By setting E nable , Preamble will be appended before the data transmitted. Refer to String Output Flowchart at /5. *IEB* Preamble Data Data1 AAZ *AAZ* (Range:0016-FF16 ASCII Code) Data2 ABA *ABA* There are two control characters ( D ata1 and D ata2 ) can be programmed for both Preamble and Postamble datas. They are appended to the data automatically when each barcode is decoded.
EXIT */$%END* Prefix/Suffix Prefix Transmission Up to 15 characters can be programed for Prefix data. The Prefix data of string will be placed after Preamble data and before the barcode data when it is E nable . Refer to String Output Flowchart at /5. Disable IGA Enable IGB Clear All IMA *IGA* *IGB* *IMA* Prefix Data Data ABF *ABF* (Range:0016-FF16 ASCII Code) Suffix Transmission Up to 15 characters can be programed for Suffix datas.
PROGRAM */$%STR* Character Insertion Add-on Insertion Disable IIA *IIA* Enable IIB *IIB* The scanner offers 2 characders of insertion between WPC and add-on code. Format WPC Add-on Insertion Add-on Add-on Insertion Data Data1 ABD *ABD* (Range:0016-FF16 ASCII Code) Data2 ABE *ABE* (Range:0016-FF16 ASCII Code) Insertion1 Data BCW Position1 *BCW* (Range:0110-4810) Data1 ABL *ABL* (Range:0016-FF16 ASCII Code) ABM The scanner offer 4 positions and 8 characters to insert among the symbol.
EXIT */$%END* Character Insertion Insertion3 Data Position3 BCY *BCY* (Range:0010-1510) Data1 ABP *ABP* (Range:0016-FF16 ASCII Code) Data2 ABQ *ABQ* (Range:0016-FF16 ASCII Code) Insertion4 Data Example Barcode "1234567" Insertion1 Insertion2 Postion Data1 2 A 5 C 1) P ROGRAM ï Position4 *BCZ* Data2 B D (Range:0010-1510) Data1 ABR *ABR* Entry programming (Range:0016-FF16 ASCII Code) Data2 2) P osition1ï 0 ï 2 ï S ET Position1 "2" ABS (Range:0016-FF16 ASCII Code) 6) I nsert Group
PROGRAM */$%STR* Other Control Code ID Translation IBA Disable *IBA* IBB If your application want to transmite Code ID, you must set this E nable . Enable *IBB* Code ID Position ICA Before Code Data *ICA* ICB After Code Data Upon your usage, the transmitting position of Code ID can be selected to place B efore or After Code Data when it transmitted.
EXIT */$%END* Other Control Inverse PROGRAM If scanner is operated in inverse barcode reading, use inverse P ROGRAM to entry scanner programming. PROGRAM */$%STR* Normal/Inverse Barcode Generally, the scanner can only Normal Barcode IPA read positive barcode signals which are printed black on white (call normal barcode).
Cable Type IBM PC, XT, AT & PS/2 Function 5p Din(M) 5p Din(F) 6p Mini Din(M)6p Mini Din(F) Clock (Host) 1 --5 --Data (Host) 3 --1 --Clock (KBD.) --1 --5 Data (KBD.
Cable Type RS-232C Function 9p D-Sub(F) 25p D-Sub(F) 8p Din(M) DC Jack(M) TxD 2 3 1 --RxD 3 2 2 --RTS 8 5 3 --CTS 7 4 4 --Shorted 4,6 6,20 ----Ground 5 7 7 2 GND Shield 5 7 7 2 VCC (+5V) 9 16,25 8 1 5 1 13 9 6 25 8 5 3 14 7 9p D-Sub(F) 1 2 4 1 6 1 25p D-Sub(F) 8p Din(M) 2 DC Jack(M) Wand Emulation Function Data Ground GND Shield VCC (+5V) 9p D-Sub(F) 2 7 8 9 5 5p Din(M) 2 3 3 1 1 9 6 6p Din(M) 2 3 3 1 3 6 3 4 2 4 5 1 5 2 1 9p D-Sub(F) 5p Din(M) 6p Din(M) 6 TTL (CMOS) 5p Din
Test Chart UPC-A 000012345670 EAN-13 (ISBN) with Add-on 5 9789572216675 00420 (ISBN: 9572216678) Code-39 (Full ASCII Code) * C O D E 3 9 T + E + S + T * (Full ASCII Code: *CODE39 Test*) Interleaved 2 of 5 12345678905 Code-93 CODE93 T E S TY d Code-128 (C Type) 0123456789 e ( U C C / E A N - 1 2 8: ] C 1 0 1 2 3 4 5 6 7 8 9 e ) Operation Manual 68
Test Chart Codabar/NW7 C98765D D43210A MSI/Plessey 1 0 5 5 8 3 0 2 5 CODE-11 8 8 6 2 6 4 7 7 7 9 7 3 3 UK/Plessey 1 6 5 2 0 0 0 3 5 4 6 1 Telepen 7 IATA 0 0 1 0 2 0 0 0 0 1 0 9 1 9 6 69 Test Chart T E L E P E N T e s t + (Numeric: 57424942534251055774888916)
Operation Manual 70
0 ASCII Code Table L H 0 0 Null 1 Up 2 1 F1 0 1 NUL DLE SOH DC1 Down F2 STX DC2 3 Left F3 ETX DC3 4 Right F4 EOT DC4 5 PgUp F5 ENQ NAK 6 PgDn F6 ACK SYN F7 BEL ETB F8 BS CAN 7 8 Bs 9 Tab A F9 HT EM F10 LF SUM B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl+ SO RS F Delete Alt+ SI US * n For keyboard wedge only.