Specifications

33
Calibration Gases, Regulators and Replacement Sensors
Single Component Calibration Gas
PART NUMBER GAS TYPE CONCENTRATION SHELF LIFE
*
VOLUME
54-9052 Cl
2
Chlorine 5 ppm 8 Months 58 liters
54-9062 Cl
2
Chlorine 5 ppm 8 Months 34 liters
54-9055 NO Nitric Oxide 30 ppm 6 Months 58 liters
54-9063 NO Nitric Oxide 30 ppm 6 Months 34 liters
54-9056 NO
2
Nitrogen Dioxide 5 ppm 6 Months 58 liters
5
4-9059
N
O
2
N
itrogen Dioxide 5 ppm 6 Months 34 liters
54-9054 HCN Hydrogen Cyanide 10 ppm 1 Year 58 liters
54-9053 HCl Hydrogen Chloride 10 ppm 1 Year 58 liters
54-9065 PH
3
Phosphine 5 ppm 6 Months 58 liters
54-9073 PH
3
Phosphine 5 ppm 6 Months 34 liters
54-9064 H
2
Hydrogen 100 ppm 5 Years 103 liters
54-9035 N
2
Nitrogen 99.9% 5 Years 103 liters
54-9039 O
2
Oxygen (Zero Air) 20.9% 5 Years 103 liters
Only for use with 12-022 regulator.
Only for use with 12-025 ammonia service regulator.
* Shelf Life figure is from date of manufacture.
Regulators
PART NO. DESCRIPTION
12-022 Regulator, 1.0 liter per minute
flow. Only for use with 54-9036
54-9045E and 54-9071E
calibration gas cylinders.
12-023 Regulator, standard service 1.0
liter per minute flow.
1
2-025
R
egulator, ammonia service 1.0
liter per minute flow.
12-030 Regulator, standard service 1.0
liter per minute flow with on/off
knob.
12-039 Demand flow regulator, standard
service, 0 – 3 liters per minute
flow
.
35-0380 AirChek 3000 PSI Regulator. 1.0
liter per minute regulator with
CGA346 hand-wheel coupling.
Can be used in conjunction with
a gas detector to conduct an air
quality check on breathing air
cylinders.
Series 3000 Replacement
Sensors, Options and Accessories
PART NO. DESCRIPTION
3101 Oxygen sensor for Model 3100.
3102 Remote Oxygen sensor for Model
3100R.
3301 Carbon monoxide sensor, CO for
Models 3300 and 3300-TP.
3350 Compressed air sampling kit with
f
ixed flow regulator
. Rated 10 –
200 psig. Specify
3
/8" Hansen “-
H” or
3
/8" Schraeder “-S” male
QD fitting when ordering.
35-179 Air sampling assembly (sensor/
calibration adapter and tubing).
35-043 Battery Eliminator (110 VAC).
35-197 Relay Closure, simply closes a cir-
cuit upon alarm condition, rated
at no more than 110 VAC and 1
amp service. Factory installation
required, must be specif
ied at
time of purchase.
6050 High-intensity remote alarm (115
dBA @ 12") Includes mounting
plate, 9V battery, test button, 6' of
cable Not intrinsically safe; may
not be used in potentially com
-
bustible environments.
55-025 Wall mounting plate for
3300-TP. A
ccepts monitor
mounted bracket.
† Standard with 3300-TP
PART NUMBER
DESCRIPTION
54-04-80 LEL Combusible Gas
54-04-90 O
2
Oxygen
••
54-04-01 CO Carbon Monoxide
54-04-02 H
2
S Hydrogen Sulfide
54-04-03 SO
2
Sulfur Dioxide
54-04-04†NH
3
Ammonia
54-04-05 CO+ Dual purpose CO/H
2
S
••
(provides a non-specific readout
for CO and H
2
S)
54-04-08
Cl
2
Chlorine
54-04-09†NO
2
Nitrogen Dioxide
54-04-10 HCN Hydrogen Cyanide
(special version of PhD Ultra required)
54-04-12
ClO
2
Chlorine Dioxide
54-04-13 PH
3
Phosphine
Special reactive gas calibration adapter (54-05-A0409) required for proper calibration.
PhD Plus
PhD Ultra
Replacement Sensors