Specifications

Cannonball Smart Sensors
PART NUMBER DESCRIPTION RANGE RESOLUTION
5
4-25-80
L
EL Combustible Gas 0 – 100% LEL 1% LEL
54-25-70 LEL Combustible Gas 0 – 100% LEL 1% LEL
54-25-71 HC-PPM LEL Combustible Gas 0 – 100% LEL see note*
54-25-90 O
2
Oxygen 0 – 30% / Vol. 0.1%
54-25-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
5
4-25-05
C
O+ CO Plus dual purpose CO: 0 – 1000 PPM 1 PPM
CO/H
2
S (provides a H
2
S: 0 – 200 PPM 1 PPM
non-specific readout
for CO and H
2
S)
54-25-19 CO-H
CO Minus, reduced 0 – 1000 PPM 1 PPM
sensitivity to H
2
54-25-02 H
2
S Hydrogen Sulfide 0 – 200 PPM 1 PPM
54-25-14 Duo-Tox Dual Channel CO/H
2
S CO: 0 – 1000 PPM 1 PPM
(provides Substance H
2
S: 0 – 200 PPM 1 PPM
specific readouts
for CO and H
2
S)
54-25-03 SO
2
Sulfur Dioxide 0 – 25 PPM 0.1 PPM
54-25-15 SO
2
-Ext. Sulfur Dioxide 0 – 100 PPM 1 PPM
extended range
54-25-21†NH
3
Ammonia 0 – 100 PPM 1 PPM
54-25-08† †† Cl
2
Chlorine 0 – 50 PPM 0.1 PPM
(non-specific)
54-25-18† †† Cl
2
Chlorine 0 – 50 PPM 0.1 PPM
(specific)
54-25-12† †† ClO
2
Chlorine Dioxide 0 – 15 PPM 0.1 PPM
(non-specific)
54-25-20 ClO
2
Chlorine Dioxide 0 – 5 PPM 0.01 PPM
(specific)
54-25-09
NO
2
Nitrogen Dioxide
0 – 50 PPM
0.1 PPM
54-25-13 PH
3
Phosphine
0 – 20 PPM 0.1 PPM
54-25-06 NO Nitric Oxide 0 – 350 PPM 1 PPM
Special reactive gas calibration adapter (54-36-16) required for proper calibration. Inert tubing is
required for proper calibration and remote sampling.
†† The non-specific Cl
2
and ClO
2
sensors can be used for the detection of both gases.
The specific Cl
2
and ClO
2
sensors are designed for the target gas only.
Cannonball3
Continuous Sample Draw Multi-Gas Detectors
26
M
ost Common Cannonball
A
ccessories
PART NO. DESCRIPTION
35-0379 Cannonball3 motorized sample
draw pump module.
35-0378 Cannonball3 motorized sample
draw pump module for dual
pump version (2 pumps). The
Cannonball3 must be config-
ured for dual pump.
35-0376 Cannonball3 Alkaline battery
pack (“D”-Cell batteries not
included).
35-0377 Cannonball3 NiMH battery
pack.
54-26-0603 Cannonball3 BioTrak Software
Kit. Includes BioTrak software
and manual.
54-26-0605S Infrared communication device
(Serial – IrDA) – Requires one
available PC serial port.
54-26-0605U Infrared communication device
(USB – IrDA) – Requires one
available USB port.
54-27-0802 TouchID
programming
kit. Includes software,
programming wand, serial
connector, 10 buttons,
10 key chain / wall mounts
for TouchID
buttons and
10 TouchID™ badges.
PC must support IrDA to download.
*
HC PPM LEL Sensor Range
RANGE RESOLUTION
0 – 9999 PPM 10 PPM
1 – 9.99% Vol .01% / Vol
% / V
ol range is dependent on calibration scale.